“…Figure 7A shows the CW Doppler scheme proposed by 32 for the detection of blood velocity in an artery; the emitter sends a frontal ultrasound wave f0 toward the flow direction with an angle of incidence θ concerning the skin surface, and when the wave is reflected by the blood, the detector perceives a change in frequency Δf given by Δf=2f0νccosθ, where ν is the speed of blood flow, c is the speed of sound over soft tissue ranging from 1540 to 1600 m/s, 33 and θ, known as the insonation angle has an approximate value of 45±4° 34,35 …”
Section: Experiments and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 7A shows the CW Doppler scheme proposed by 32 for the detection of blood velocity in an artery; the emitter sends a frontal ultrasound wave f0 toward the flow direction with an angle of incidence θ concerning the skin surface, and when the wave is reflected by the blood, the detector perceives a change in frequency Δf given by Δf=2f0νccosθ, where ν is the speed of blood flow, c is the speed of sound over soft tissue ranging from 1540 to 1600 m/s, 33 and θ, known as the insonation angle has an approximate value of 45±4° 34,35 …”
Section: Experiments and Resultsmentioning
confidence: 99%
“…where ν is the speed of blood flow, c is the speed of sound over soft tissue ranging from 1540 to 1600 m/s, 33 and θ, known as the insonation angle has an approximate value of 45 AE 4 . 34,35 Regarding the velocity in a normal artery, the peak velocity in systole takes hundredths of a second after the stage of contraction of the ventricular chamber. The blood velocity profile provides three speeds: time average maximum speed (TAMV), systolic or peak velocity (PSV), and end-diastolic velocity (EDV).…”
Section: Doppler Signal Conditioningmentioning
confidence: 99%
“…However, 2D-US is limited by the fact that its plane image can only show one side of the fetus, with limited detection metrics [16]. Studies have shown that the missed diagnosis or misdiagnosis of fetal craniocerebral abnormalities may be due to artifacts caused by umbilical cord interference [17]. Therefore, if fetal abnormalities are suspected on 2D-US and clearer images are needed for further evaluation, an examination modality with more advanced imaging capabilities is required.…”
Section: Introductionmentioning
confidence: 99%
“…Ultrasound testing, as the most commonly used non-invasive method of prenatal examination, plays an important role in fetal cardiac malformation and chromosome screening (8,9). Two-dimensional ultrasonography is commonly applied in the screening of fetal cardiac malformation and chromosomal abnormalities, but it has defect due to the limitation that its planar image can only display one side of the fetus and can only detect limited indexes (10,11). Compared with conventional Diagnostic value of four-dimensional ultrasonography with STIC combined with two-dimensional ultrasonography for fetal cardiac malformation and chromosomal abnormalities in early pregnancy two-dimensional ultrasonography diagnosis, four-dimensional ultrasonography with spatio-temporal image correlation (STIC) technology can offer a more comprehensive and intuitive observation of the fetal heart dynamically or statically (12).…”
Section: Introductionmentioning
confidence: 99%