2018
DOI: 10.1016/j.jmmm.2017.10.025
|View full text |Cite
|
Sign up to set email alerts
|

Size optimization for complex permeability measurement of magnetic thin films using a short-circuited microstrip line up to 30 GHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…Commonly, the magnetization precessions in magn etic materials are in-phase (namely the acoustic mode) in the low-frequency regions [6,11], which is already familiar to researchers. In recent years, due to technical innovation, the applications of ferromagnetic resonance have developed rapidly towards the high-frequency regions [16][17][18][19], and ultrahigh ferromagnetic resonance is in urgent demand as it has a great advantage in the research of more advanced devices [20]. The magnetization precessions in magnetic materials are out-of-phase (namely the optical mode) in the high-frequency regions because of the contribution of exchange-coupling interaction [21,22].…”
Section: Introductionmentioning
confidence: 99%
“…Commonly, the magnetization precessions in magn etic materials are in-phase (namely the acoustic mode) in the low-frequency regions [6,11], which is already familiar to researchers. In recent years, due to technical innovation, the applications of ferromagnetic resonance have developed rapidly towards the high-frequency regions [16][17][18][19], and ultrahigh ferromagnetic resonance is in urgent demand as it has a great advantage in the research of more advanced devices [20]. The magnetization precessions in magnetic materials are out-of-phase (namely the optical mode) in the high-frequency regions because of the contribution of exchange-coupling interaction [21,22].…”
Section: Introductionmentioning
confidence: 99%
“…We have already reported such measurement results for the 10-30 GHz band using short-circuited microstrip line test fixtures. 1,2) Improving the present fixtures is crucial for performing measurements at higher frequencies. On the other hand, a short-circuited coaxial line can also be used, without the need to consider the external noise due to a perfectly shielded structure.…”
Section: Introductionmentioning
confidence: 99%
“…For these films, the in-plane magnetization curves were measured with a vibrating sample magnetometer (VSM), as shown in Figs. 2(a)-2(c), and the relative permeabilities were measured with a short-circuited MSL measurement, 29) as shown in Fig. 2(d)-2(f).…”
mentioning
confidence: 99%