Six of one, half a dozen of the other: A measure of multidisciplinary inter/intra-rater reliability of the society for fetal urology and urinary tract dilation grading systems for hydronephrosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

3
4

Authors

Journals

citations
Cited by 40 publications
(19 citation statements)
references
References 17 publications
0
19
0
Order By: Relevance
“…When comparing mild (0, I, II) and severe (III, IV) HN images, our model achieved an average accuracy of 78%, which is well above chance level. When the model discriminated between moderate grades (II and III), which is less reliable for physicians (12,13), performance only dropped to 71%. There is no direct comparison to be made against physician accuracy, however, considering the known difficulties in distinguishing between moderate HN grades (12,13), these results are encouraging.…”
Section: Binary Classification Performancementioning
confidence: 94%
See 3 more Smart Citations
“…When comparing mild (0, I, II) and severe (III, IV) HN images, our model achieved an average accuracy of 78%, which is well above chance level. When the model discriminated between moderate grades (II and III), which is less reliable for physicians (12,13), performance only dropped to 71%. There is no direct comparison to be made against physician accuracy, however, considering the known difficulties in distinguishing between moderate HN grades (12,13), these results are encouraging.…”
Section: Binary Classification Performancementioning
confidence: 94%
“…Further investigation into the output of our model reveals that there are many borderline images where there is not an obvious choice for which class the image belongs to (e.g., Figures 3A,C). In cases such as these where two grades possible are, it must choose a single HN grade according to the SFU system, much like a physician (12,13).…”
Section: Five-way Classification Performancementioning
confidence: 99%
See 2 more Smart Citations
“…The SFU grading system has problems with inter-and intra-rater variability [16,29]. We tried to minimize the problems by adopting a second single reviewer for all ultrasonography ndings; however, the reliability problem for grades 2 and 3 remains [16,30]. Further studies are needed to overcome these limitations and con rm the ndings of the present study.…”
Section: Discussionmentioning