XIV International Conference on Pulsed Lasers and Laser Applications 2019
DOI: 10.1117/12.2548426
|View full text |Cite
|
Sign up to set email alerts
|

Situation and prospect of light and miniature UAV-borne LiDAR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The on-line and off-line wavelength optimization is very important to minimize the expected error for the IPDA lidar system. Xie et al [39] investigated the sensitivity of the measurement error of CO 2 column concentration versus wavelength in terms of both random and systematic errors, where the wavelength optimization was carried out to minimize the total error of the lidar system to detect CO 2 column concentration. As the inversion principle of CH 4 is similar to that of CO 2 [38], therefore, a similar optimization algorithm has been employed in this paper to optimize the on-line and off-line wavelengths.…”
Section: On-line and Off-line Wavelength Optimizationmentioning
confidence: 99%
See 1 more Smart Citation
“…The on-line and off-line wavelength optimization is very important to minimize the expected error for the IPDA lidar system. Xie et al [39] investigated the sensitivity of the measurement error of CO 2 column concentration versus wavelength in terms of both random and systematic errors, where the wavelength optimization was carried out to minimize the total error of the lidar system to detect CO 2 column concentration. As the inversion principle of CH 4 is similar to that of CO 2 [38], therefore, a similar optimization algorithm has been employed in this paper to optimize the on-line and off-line wavelengths.…”
Section: On-line and Off-line Wavelength Optimizationmentioning
confidence: 99%
“…Bousquet and Ehret et al [35,38] have carried out error budgeting for methane gas measurement from the perspective of random and systematic errors. Xie et al [39] have proposed a wavelength optimization model of IPDA lidar systems for CO 2 detection. The MERLIN team, the first international developer of a methane detection satellite lidar, has also estimated methane detection errors for different regions of the world, where Kiemle et al have evaluated the entire IPDA system performance and has studied the sensitivity for MERLIN [40,41], resulting in better detection accuracy than the GOSAT passive remote sensing satellite [35].…”
Section: Introductionmentioning
confidence: 99%
“…However, since the UAV can be operated at a very low flight speed with great overlap between the tracks and variable flight altitude, the resulting sample point density can be very high (~250 points/m 2 ). Another feature is the wide scanning angle of the small field of view (FOV) of LiDAR RIEGL VUX-1UAV [128]. 2D-4 D geomorphic characteristics such as the walls of mountains, micro-morphological structures and textures, landslide mapping or the monitoring of soil erosions can be sampled with a high density of pulses [129].…”
Section: Lidar and Radar Altimetersmentioning
confidence: 99%
“…Temporal resolutions as low as just a few ps have been demonstrated using single photon superconducting nanowires detectors (SNSPDs) 8 , with commercial solutions offering ~40 ps resolution 9 . Although this technology allows for unprecedented levels of performance, they required cryogenic cooling which makes their footprint prohibitively high for important applications such as for sensing and LiDAR applications from unmanned aerial vehicles (UAVs) 10 , for energy efficient centers for future quantum communications 11 , or for practical medical applications in care facilities 6,12 . For such applications, there has been notable advances in the development of low energy consumption and compact single-photon detector, namely through integrated and on-chip solutions based on single photon avalanched detectors (SPADs) 13,14 .…”
Section: Introductionmentioning
confidence: 99%