Integrated Surface and Ground Water Management 2001
DOI: 10.1061/40562(267)32
|View full text |Cite
|
Sign up to set email alerts
|

Siting, Design and Operation of Infiltration BMPs: A Case Study

Abstract: This paper reports on experiences with infiltration basin and trenches constructed and operated as part of the Caltrans Best Management Practice (BMP) Retrofit Pilot Study Program. Fifty-two sites adjacent to highways and maintenance facilities in the Los Angeles and San Diego areas were evaluated and two infiltration basins and two infiltration trenches were constructed. One basin and one trench successfully met design expectations, which in California includes a 3-day drain time to prevent mosquito breeding.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…Decrease in infiltration capacity due to accumulation of sediment that leads to increase in duration of water ponding incidents and discharge frequencies have been demonstrated by both short-term (up to 3 years) and long-term (10-15 years) in situ infiltration experiments and numerical simulations (Warnaars et al 1999;Dechesne et al 2005;Le Coustumer and Barraud 2007;Emerson et al 2010;Gonzalez-Merchan et al 2010;Lassabatere et al 2010;Bergman et al 2011). Failure of an infiltration basin is attributed to improper siting, absence of pretreatment, excess sediment inputs, and improper and irregular maintenance (Currier et al 2001;Stormwater Manager's Resource Center 2008). However, some infiltration basins have been reported to be operational with good infiltration capacities after 21 years (Dechesne et al 2005) and even after 100 years (Warnaars et al 1999).…”
Section: Introductionmentioning
confidence: 99%
“…Decrease in infiltration capacity due to accumulation of sediment that leads to increase in duration of water ponding incidents and discharge frequencies have been demonstrated by both short-term (up to 3 years) and long-term (10-15 years) in situ infiltration experiments and numerical simulations (Warnaars et al 1999;Dechesne et al 2005;Le Coustumer and Barraud 2007;Emerson et al 2010;Gonzalez-Merchan et al 2010;Lassabatere et al 2010;Bergman et al 2011). Failure of an infiltration basin is attributed to improper siting, absence of pretreatment, excess sediment inputs, and improper and irregular maintenance (Currier et al 2001;Stormwater Manager's Resource Center 2008). However, some infiltration basins have been reported to be operational with good infiltration capacities after 21 years (Dechesne et al 2005) and even after 100 years (Warnaars et al 1999).…”
Section: Introductionmentioning
confidence: 99%