2006
DOI: 10.1016/j.bios.2005.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Site-directed immobilisation of antibody fragments for detection of C-reactive protein

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
51
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 78 publications
(55 citation statements)
references
References 30 publications
4
51
0
Order By: Relevance
“…AuNPs on the surface have increased the sensitivity of the sensor. This method is more sensitive compared with other measurement methods based on related data have shown that (Meyer et al, 2002, Meyer et al, 2007Vikholm-Lundin et al, 2006). 87fM be determined until this study, low-range signal.…”
Section: Qcm Based Biosensors Developed For Determination Of Crpmentioning
confidence: 79%
“…AuNPs on the surface have increased the sensitivity of the sensor. This method is more sensitive compared with other measurement methods based on related data have shown that (Meyer et al, 2002, Meyer et al, 2007Vikholm-Lundin et al, 2006). 87fM be determined until this study, low-range signal.…”
Section: Qcm Based Biosensors Developed For Determination Of Crpmentioning
confidence: 79%
“…Enzymatic digestion of an Ab followed by chemical reduction has yielded Fab fragments with exposed active sulfhydryl groups. Direct bonding between the sulfhydryl group and a gold surface, as well as thiol-specific cross-linking on non-metallic surfaces has been reported [20,21].…”
Section: Fig (3)mentioning
confidence: 98%
“…The non-ionic hydrophilic polymer of N-[tris(hydroxymethyl)methyl]acrylamide, pTHMMAA used to suppress non-specific binding to antibody layers were prepared as previously described (Vikholm-Lundin and Albers, 2006). Recombinant anti-morphine M1 antibody Fab fragments has been enriched from phage display library as described previously (Pulli et al, 2005).…”
Section: Production Of Lipoate Polymer and Recombinant Anti-morphinementioning
confidence: 99%
“…Coupling of the antibody Fab fragments onto the sensor surface is simple and fast and can be used for attaching any antibody in an oriented manner to the sensor surface. The immobilisation method has also been demonstrated for antibody fragments specific for C reactive protein (Vikholm-Lundin and Albers, 2006). The layer shows a 5-fold higher response to antigen than antibody F(ab) 2 -fragments that are randomly adsorbed on the sensor surface.…”
Section: Introductionmentioning
confidence: 96%