2021
DOI: 10.1016/j.diii.2021.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Single-source dual energy CT to assess myocardial extracellular volume fraction in aortic stenosis before transcatheter aortic valve implantation (TAVI)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
10
0
7

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 35 publications
2
10
0
7
Order By: Relevance
“…Altogether, the ECV values reported in the present study are in line with the data available with CMR. This is not a surprising finding, considering the high concordance between these modalities for ECV quantification as demonstrated by recent comparative studies which permits the use of this biomarker for multiple prospects [8,11,14,21]. Hence, we showed recently that ECV enabled by DECT allows a prediction of cardiac complications in acute myocarditis [34].…”
Section: Discussionsupporting
confidence: 64%
See 2 more Smart Citations
“…Altogether, the ECV values reported in the present study are in line with the data available with CMR. This is not a surprising finding, considering the high concordance between these modalities for ECV quantification as demonstrated by recent comparative studies which permits the use of this biomarker for multiple prospects [8,11,14,21]. Hence, we showed recently that ECV enabled by DECT allows a prediction of cardiac complications in acute myocarditis [34].…”
Section: Discussionsupporting
confidence: 64%
“…The novelty of the present study is the use of CT in a suspected population of myocarditis and as so the report of ECV values which can be the starting point for its implementation in clinical routine. In the same line, few studies have reported the ECV values of different cardiopathies such as heart failure, global cardiomyopathies, cardiac amyloidosis or in aortic stenosis patients [ 14 , 21 , 22 ]. Taken together, these studies are holding great promises for cardiac CT imaging because of its many advantages.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…We found median ECV values of 30.5%, which is in good agreement with values reported in the literature for patients with severe aortic stenosis. 6,7,11,34 Considering the transmural ECV gradients, we found significant endoepicardial gradients for the anterior, lateral, and posterior walls of the left ventricle. This fibrosis gradient has already been previously described in patients with severe aortic stenosis and may be reflective of a reparative response to low-endocardial perfusion and consecutive myocardial ischemia.…”
Section: Discussionmentioning
confidence: 78%
“…Измерение ВММ основано на измерении разницы в концентрации внеклеточного индикатора (в случае методов лучевой диагностики -контрастного препарата) между миокардом и кровотоком в момент равновесной концентрации в сочетании с измерением объема распределения крови (традиционно оценивается как: 1-уровень гематокрита (Ht)) [6,7].…”
Section: Introductionunclassified