2010
DOI: 10.1016/j.conbuildmat.2010.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Single-side access tomography for evaluating interior defect of concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0
4

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 42 publications
(25 citation statements)
references
References 11 publications
0
21
0
4
Order By: Relevance
“…Moreover, the high permittivity of the asteroid minerals [17,18,19,20] is likely to lead to strongly randomized or noisy reflections ‡ due to which the present inversion strategy utilizing the direct part of the signal can be advantageous [5]. In addition to asteroid tomography, other potential applications of the present sparse source inversion approach include on-site material testing and inspection [21,22,23,24,25,26,27], biomedical ultrasonography [28,29,30,31,32], as well as plenty of atmospheric, pedospheric, geological, and biological investigations utilizing travel time data [33,34,35], such as recovery of the root-zone structure of a tree [36]. The objectives above were studied in a laboratory experiment in which three 22-41 mm onyx stones were to be detected from the central part of a 150 mm synthetic reson cube based on travel time of a 55 kHz (35 mm wavelength) ultrasonic signal.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the high permittivity of the asteroid minerals [17,18,19,20] is likely to lead to strongly randomized or noisy reflections ‡ due to which the present inversion strategy utilizing the direct part of the signal can be advantageous [5]. In addition to asteroid tomography, other potential applications of the present sparse source inversion approach include on-site material testing and inspection [21,22,23,24,25,26,27], biomedical ultrasonography [28,29,30,31,32], as well as plenty of atmospheric, pedospheric, geological, and biological investigations utilizing travel time data [33,34,35], such as recovery of the root-zone structure of a tree [36]. The objectives above were studied in a laboratory experiment in which three 22-41 mm onyx stones were to be detected from the central part of a 150 mm synthetic reson cube based on travel time of a 55 kHz (35 mm wavelength) ultrasonic signal.…”
Section: Introductionmentioning
confidence: 99%
“…biomedical microwave or ultrasonic imaging [5,6,7,8,9] and on-site material testing and inspection [10,11,12,13]. Our focus was on the first one with the central objective to find a robust imaging approach that can be implemented within a restricted in situ energy supply and tight mission payload limits [14].…”
Section: Introductionmentioning
confidence: 99%
“…Styrofoam plates of 300 mm diameter were included at specific locations. The same specimen was used for a different purpose, as reported elsewhere [26]. In order to simulate boundary free experiment, in this current study the measurements were limited to two 200 Â 200 Â 300 mm 3 portions near the middle of the specimen, which included one quarter of the defect.…”
Section: Experiments Detailmentioning
confidence: 99%