2023
DOI: 10.1016/j.ijepes.2022.108699
|View full text |Cite
|
Sign up to set email alerts
|

Single phase to ground fault location method of overhead line based on magnetic field detection and multi-criteria fusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…In (3), "∏" represents the logical "or" operation; K s1 and K s2 represent the power switching coefficient, indicating whether the power supply in the upstream and downstream areas of switch j is connected to the distribution network. C j,s1 represents the status of the feeder section included in the path from the switch j to the upstream area power supply S 1 , and C j,s2 represents the status value of the feeder section included in the path from the switch j to the downstream area power supply S 2 .…”
Section: Switching Functionmentioning
confidence: 99%
See 1 more Smart Citation
“…In (3), "∏" represents the logical "or" operation; K s1 and K s2 represent the power switching coefficient, indicating whether the power supply in the upstream and downstream areas of switch j is connected to the distribution network. C j,s1 represents the status of the feeder section included in the path from the switch j to the upstream area power supply S 1 , and C j,s2 represents the status value of the feeder section included in the path from the switch j to the downstream area power supply S 2 .…”
Section: Switching Functionmentioning
confidence: 99%
“…Distribution network is an important link between power transmission systems and users 1,2 . Different from transmission network, distribution network is radial, has a large number of branches and usually leads to failure due to adverse weather conditions, bird contacts and human actions 3,4,5 . Therefore, many researchers have been committed to developing efficient fault location methods to provide effective guidance for maintainers 6,7 .…”
Section: Introductionmentioning
confidence: 99%
“…For economic operation considerations, the non-effectively grounded neutral points have been adopted in the medium-voltage (MV) distribution network design in China [1]. With widespread application of such system in the grid, fault line identification and fault point location have great significance for maintaining power system reliability and ensuring network equipment safety [2,3]. Single-phase-to-ground fault is the most common fault in distribution system.…”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of those sensors is easily affected by partial discharge, the stability of the output signal is poor, and due to size and power constraints, these sensors are difficult to integrate into fault indicators. As a result of the low reliability of voltage sensing, the accuracy rate of SLG fault identification in DS are greatly limited, which is less than 60% at practice [1][2][3][4][5] .…”
Section: Introductionmentioning
confidence: 99%