2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289)
DOI: 10.1109/psec.2002.1023074
|View full text |Cite
|
Sign up to set email alerts
|

Single-phase PQ theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
28
0
1

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(29 citation statements)
references
References 6 publications
0
28
0
1
Order By: Relevance
“…It is calculated considering the amplitude detection of the PLL system. According to the single-phase PQ theory [13,14,31,34], the active and reactive power can be controlled independently in the outer power control loop, and then the grid current references are generated, being a dual-loop control structure [30]. In order to regulate the power reference, an OSG system is needed to generate the quadrature components, vα and vβ.…”
Section: Control Strategy In Zero-voltage Ride-through Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…It is calculated considering the amplitude detection of the PLL system. According to the single-phase PQ theory [13,14,31,34], the active and reactive power can be controlled independently in the outer power control loop, and then the grid current references are generated, being a dual-loop control structure [30]. In order to regulate the power reference, an OSG system is needed to generate the quadrature components, vα and vβ.…”
Section: Control Strategy In Zero-voltage Ride-through Operationmentioning
confidence: 99%
“…The conventional dual-loop control structure in single-phase PV systems could be applied under the grid fault by directly calculating the current references [30]. When the instantaneous power theory is adopted in single-phase PV systems, the single-phase instantaneous active and reactive powers (PQ) theory [31] can be used to independently control the active and reactive power under LVRT as reported in [11][12][13][14]. In addition, the droop control methods could be considered as an alternative for regulating the active and reactive power under the grid fault [32], on condition that the grid is mainly inductive.…”
mentioning
confidence: 99%
“…As it is introduced in [19]- [21], to obtain the same representation for single-phase systems, the fictitious vectors v g (t) and i o (t) are created by applying a phase shift of π/2 to the original signals as it is represented in the complex plane of figure 4. Thus, the real components of current and voltage are the instantaneous values of each v g (t) and i o (t) whereas the imaginary components are instantaneous values of its orthogonal versions v g (t) and i o (t).…”
Section: Modified Single Phase Pq Theorymentioning
confidence: 99%
“…The instantaneous p -q theory is expanded from the concept of single phase p-q theory [5], [6], [10], [19] and the corresponding voltage equations are mentioned below in eq. (1), (2) & (3).…”
Section: The Control Strategy For the Series Apf'smentioning
confidence: 99%