2011
DOI: 10.1364/oe.19.019169
|View full text |Cite
|
Sign up to set email alerts
|

Single-grating monochromator for extreme-ultraviolet ultrashort pulses

Abstract: Extreme-ultraviolet high-order-harmonic pulses with 1.6·10(7) photons/pulse at 32.5 eV have been separated from multiple harmonic orders by a time-preserving monochromator using a single grating in the off-plane mount. This grating geometry gives minimum temporal broadening and high efficiency. The pulse duration of the monochromatized harmonic pulses has been measured to be in the range 20 to 30 fs when the harmonic process is driven by an intense 30 fs near-infrared pulse. The harmonic photon energy is tunab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
141
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 156 publications
(147 citation statements)
references
References 32 publications
0
141
0
Order By: Relevance
“…The latter were obtained by high harmonic generation in an Argon gas jet. The 17th harmonic athω probe = 26.3 eV was selected with a time-preserving grating monochromator [13] and used to measure photoelectron distributions from the sample. The probe polarization was fixed along the x axis [ Fig.…”
mentioning
confidence: 99%
“…The latter were obtained by high harmonic generation in an Argon gas jet. The 17th harmonic athω probe = 26.3 eV was selected with a time-preserving grating monochromator [13] and used to measure photoelectron distributions from the sample. The probe polarization was fixed along the x axis [ Fig.…”
mentioning
confidence: 99%
“…[20][21][22] The fundamental laser, a multi-pass titanium-sapphire amplifier, produced up to 10 mJ, 800 nm pulses with a FWHM of 30 fs at 1 kHz. For time resolved measurements the laser output was split 20:80 for probe:pump (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…A full description of the monochromator is given elsewhere. 22 The measurements presented here used a grating with groove density of 500 gr/mm and a theoretical energy resolution of E = 1.0 eV at 62 eV.…”
Section: A Monochromation and Calibrationmentioning
confidence: 99%
“…The OPM gives higher throughput than the CDM, since it has been theoretically demonstrated and experimentally measured that the OPM peak diffraction efficiency is close to the reflectivity of the coating at the altitude angle [29,30]. Both geometries have still been applied to the realization of ultrafast monochromators for HHs in the XUV [31][32][33][34]. Since the gratings in the OPM monochromators are operated in parallel light, we will compare the two configurations with plane gratings.…”
Section: Single-grating Monochromators For Ultrashort Pulsesmentioning
confidence: 99%