2017
DOI: 10.1103/physreva.95.042702
|View full text |Cite
|
Sign up to set email alerts
|

Single-electron capture in 3-keV/uAr8+-He collisions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 35 publications
1
5
0
Order By: Relevance
“…Figure 3 shows comparisons of the 4l population fractions between the measurements and the results calculated by analytical l distributions, which are the so-called statistical, low-energy, separable, Landau-Zener (LZ), and even distributions. For the present measurements, the relative errors are less than 7% and the measured results are in good agreement with the existing COLTRIMS measurements (Abdallah et al 1998;Zhang et al 2017) and spectroscopic measurements (Druetta et al 1987). Note that the measured fractions show a strong dependence on collision energy, while the results calculated using these l distributions are independent of collision energy.…”
Section: Resultssupporting
confidence: 90%
See 1 more Smart Citation
“…Figure 3 shows comparisons of the 4l population fractions between the measurements and the results calculated by analytical l distributions, which are the so-called statistical, low-energy, separable, Landau-Zener (LZ), and even distributions. For the present measurements, the relative errors are less than 7% and the measured results are in good agreement with the existing COLTRIMS measurements (Abdallah et al 1998;Zhang et al 2017) and spectroscopic measurements (Druetta et al 1987). Note that the measured fractions show a strong dependence on collision energy, while the results calculated using these l distributions are independent of collision energy.…”
Section: Resultssupporting
confidence: 90%
“…For instance, Beiersdorfer et al (2000) have measured the hardness ratios of the X-ray emissions following CX between 10 bare and hydrogenic ions up to U 91+ and neutrals, and found that the assumptions of the statistical distribution break down at low collision energies. Another significant method is the cold target recoil ion momentum spectroscopy (COLTRIMS) detecting technique (Dörner et al 2000;Ullrich et al 2003), which has advanced the measurement of CX to the point where n- (Ali et al 2010;Xu et al 2021) and l-state selectivity can be resolved (Fisher et al 2002;Zhang et al 2017). However, few measurements are reported particularly for l-resolved capture.…”
Section: Introductionmentioning
confidence: 99%
“…Experiments on CX between O 6+ and He and H 2 were performed with the COLTRIMS apparatus mounted on the 320 kV high-voltage platform for multidisciplinary research with HCIs at the Institute of Modern Physics, Chinese Academy of Sciences (IMP-CAS), shown in Figure 1. The working principles of COLTRIMS have been described in detail elsewhere (Dörner et al 2000;Ullrich et al 2003;Ma et al 2011;Zhang et al 2016Zhang et al , 2017Guo et al 2021).…”
Section: Methodsmentioning
confidence: 99%
“…The concept of the contact has been recently extended to the case with the p-wave interaction [56][57][58][59][60][61]. One of the most remarkable difference from the s-wave contact is that in the p-wave case, the contacts consist of 6 components, in principle, because the p-wave interaction consist of three components and each component is characterized by two parameters, the p-wave scattering volume and the effective range.…”
Section: Introductionmentioning
confidence: 99%