1989
DOI: 10.1016/s0022-5347(17)40669-0
|View full text |Cite
|
Sign up to set email alerts
|

Single-Dose Captopril Scintigraphy in the Diagnosis of Renovascular Hypertension

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0
8

Year Published

1989
1989
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(45 citation statements)
references
References 0 publications
0
37
0
8
Order By: Relevance
“…The accuracy of captopril renography in identifying patients with renovascular disease has been variable, with reported sensitivities of approximately 85% (range 45% to 94%) and specificities of approximately 93% (range 81% to 100%) (674)(675)(676)(677)(678)(679)(680)(681)(682)(683)(684)(685).…”
Section: Class I 1 Duplex Ultrasonography Is Recommended As a Screenmentioning
confidence: 99%
“…The accuracy of captopril renography in identifying patients with renovascular disease has been variable, with reported sensitivities of approximately 85% (range 45% to 94%) and specificities of approximately 93% (range 81% to 100%) (674)(675)(676)(677)(678)(679)(680)(681)(682)(683)(684)(685).…”
Section: Class I 1 Duplex Ultrasonography Is Recommended As a Screenmentioning
confidence: 99%
“…Among these 4, two kidneys had stenosis of accessory RA with normal main RA and one kidney was poorly functioning. 11 Captopril Tc99m-DTPA Sensitivity-80%, Specificity-100% Nally JV et al (1988) 12 Captopril Tc99m-DTPA Sensitivity-100%, Specificity-100% Safakianakis GN (1989) 13 Captopril-131-OIH Sensitivity-100%, Specificity-100% Svetkey LP et al (1989) 14 Captopril Tc99m-DTPA Captopril-131-OIH Sensitivity-91%, Specificity-50% Sensitivity-80%, Specificity-42% Charles C et al (1990) 15 Captopril Tc99m-DTPA Without Captoril Sensitivity-91%, Specificity-93% Sensitivity-43-68% Kakizaki H et al (1992) 16 Captopril Tc99m-DTPA Sensitivity-86%, Specificity-100% Man SJ etv al (1992) 17 Captopril Tc99m-DTPA Sensitivity-93%, Specificity-95% 18 …”
Section: Resultsmentioning
confidence: 99%
“…23 Sfakianakis NG et al (1987) compared 131 I-iodohippurate (OIH) and Tc99m-DTPA Scintigraphy in same patient and showed that scintigraphy with OIH scintigraphy with OIH appears to be more sensitive and specific than DTPA and concluded that OIH scintigraphy with captopril may provide a rapid and sensitive screening test for RVH. 24 Fommei E at al (1987) reported positive captopril induced changes in Tc99m-DTPA scintigraphy which predicted patients who can be cured by revascularization or percutaneous transfemoral renal angioplasty (PTRA). 25 Mann S J et al (1991) compared usefulness of 131 I-OIH scintigraphy to be more accurate than Tc99m-DTPA.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations