2021
DOI: 10.1016/j.athoracsur.2020.08.039
|View full text |Cite
|
Sign up to set email alerts
|

Single Center Five Years’ Experience of Ozaki Procedure: Midterm Follow-up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
21
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(29 citation statements)
references
References 23 publications
6
21
0
1
Order By: Relevance
“…In patients with isolated aortic stenosis, Iida and colleagues report a mean peak pressure gradient of 22 ± 10.7 mmHg one week after the procedure and 19.2 ± 9.7 mmHg after 20 months [8]. In our cohort, after median 21 months of followup, median (IQR) mean and peak gradients were 6 (5,9) mmHg and 12 (8, 17) mmHg, respectively; these results are similar to recently published data from a US center [12].…”
Section: Hemodynamicsupporting
confidence: 90%
See 2 more Smart Citations
“…In patients with isolated aortic stenosis, Iida and colleagues report a mean peak pressure gradient of 22 ± 10.7 mmHg one week after the procedure and 19.2 ± 9.7 mmHg after 20 months [8]. In our cohort, after median 21 months of followup, median (IQR) mean and peak gradients were 6 (5,9) mmHg and 12 (8, 17) mmHg, respectively; these results are similar to recently published data from a US center [12].…”
Section: Hemodynamicsupporting
confidence: 90%
“…Even if several new study groups have recently confirmed AVNeo to be a safe and reproducible technique, the key question is durability. Data regarding this are limited to date [12][13]14•].…”
Section: Durabilitymentioning
confidence: 99%
See 1 more Smart Citation
“…Similar results have been observed in other series. 10,18,[21][22][23] This excellent hemodynamic performance is the result of preserving the natural motion of the aortic valve annulus and the coordination of the left ventricle, aortic annulus, sinus of Valsalva, and aorta. This is particularly important in patients with a small AV annulus.…”
Section: Hemodynamic Performancementioning
confidence: 99%
“…In cardiac surgery, for example the technique inclusive of Ozaky procedure, the aortic valve repair using neocuspidalization, require intraoperative taken fresh autologous pericardium patch before implant. Usually, the pericardium is immersed in aqueous solution with GA concentration up to 600 ppm, and then it is washed [13,14]. After that, the treated pericardium is anchored to the patient's aortic tissues as a function of the new apparatus valvular.…”
Section: Ga Use For Autologous Pericardial Patchmentioning
confidence: 99%