Single and multiscale detection of masses in digital mammograms

Abstract: Scale is an important issue in the automated detection of masses in mammograms, due to the range of possible sizes masses can have. In this work, it was examined if detection of masses can be done at a single scale, or whether it is more appropriate to use the output of the detection method at different scales in a multiscale scheme. Three different pixel-based mass-detection methods were used for this purpose. The first method is based on convolution of a mammogram with the Laplacian of a Gaussian, the second… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
58
0
1

Year Published

2005
2005
2016
2016

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 112 publications
(59 citation statements)
references
References 17 publications
0
58
0
1
Order By: Relevance
“…Brake et al in 1999 [12] proposed a multi-scale approach which we use in our study. Multiple templates of different sizes are used and the correlation to each template is calculated.…”
Section: B Related Workmentioning
confidence: 99%
“…Brake et al in 1999 [12] proposed a multi-scale approach which we use in our study. Multiple templates of different sizes are used and the correlation to each template is calculated.…”
Section: B Related Workmentioning
confidence: 99%
“…For example, te Brake and Karssemeijer [15] extend the circular template to 1.3R, where R is the radius of the model of the lesion, and brightness of the ring surrounding the model is zero. A more general template using a sector-form model is considered by Hatanaka et al [16], who analyze detection of masses with a partial loss of region in the vicinity of film edge.…”
Section: Optimization Of Brightness Distributionmentioning
confidence: 99%
“…In that paper, tests are made on 17 mammograms containing circumscribed masses. The paper by te Brake and Karssemeijer [15] considers a larger dataset of 132 mammograms containing malignant masses. The paper is mainly concerned with comparison of single and multiscale detection of masses and concludes that multiscale gives a slight improvement.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 3 shows this process. First, a rough region of the lesion is estimated by a template matching [21][22][23] and a thresholding method. The internal and external markers are then determined by distance transformation and morphological operation, respectively.…”
Section: Determination Of Internal and External Markersmentioning