1985
DOI: 10.1088/0022-3700/18/2/010
|View full text |Cite
|
Sign up to set email alerts
|

Single and double photoionisation of Ca atoms between 35 and 42 nm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
23
0

Year Published

1987
1987
2007
2007

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 77 publications
(24 citation statements)
references
References 13 publications
1
23
0
Order By: Relevance
“…The background pressure in the experimental chamber was kept below 1.0×10 −7 Torr. The photoions were detected by a time of flight (TOF) mass spectrometer 25 mounted perpendicular to both the atomic and photon beams, operating in a pulsed extraction mode. The charge-state resolved photoion yield spectra of K + and K 2+ were measured by gated collection of the photoion TOF data obtained in each step of the photon energy scan.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…The background pressure in the experimental chamber was kept below 1.0×10 −7 Torr. The photoions were detected by a time of flight (TOF) mass spectrometer 25 mounted perpendicular to both the atomic and photon beams, operating in a pulsed extraction mode. The charge-state resolved photoion yield spectra of K + and K 2+ were measured by gated collection of the photoion TOF data obtained in each step of the photon energy scan.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…The quantities a and b are the interacting and non-interacting continuum cross sections [1]. figure 1, we find that the first member of the series, the 1s 2 2s2p 5 ( 1 P)3p 2 ( 1 P o ) state, appears as a window type resonance in the single ionization channel. This indicates that the excitation probability of this state is very small compared to the 2p ionization.…”
Section: Resultsmentioning
confidence: 84%
“…The details of the experimental apparatus and procedure have been described in previous papers [2,3]. Briefly, a time-of-flight mass spectrometer was used to separate ions with different charges.…”
Section: Methodsmentioning
confidence: 99%
“…The monochromatized photons entered into the experimental apparatus, which consisted of an ion time of flight (ITOF) mass spectrometer and an electron bombardment oven [18]. A positive pulsed electric field was applied to push ions into the flight tube and the ions were detected with a microchannel plate (MCP).…”
mentioning
confidence: 99%
“…To minimize the production of uncontrollable thermal electrons at high temperature, the radiation shield of the oven was water cooled and the distance between the oven and the filament was made larger compared to our previous version [18]. These improved the stability of the beryllium atomic vapor generation.…”
mentioning
confidence: 99%