2019
DOI: 10.1007/s00604-019-3750-9
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous voltammetric determination of hydroquinone and catechol by using a glassy carbon electrode modified with a ternary nanocomposite prepared from oxidized multiwalled carbon nanotubes, manganese dioxide and manganese ferrite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 33 publications
1
5
0
Order By: Relevance
“…All the linear equations, linear correlation coefficient (R 2 ), and detection limits were listed in Table SI (see in Supplementary Information). The detection limits of CAT and HQ on NanoAu/Poly(ABSA)/MWCNTs/GCE were close or smaller than those from most of literature reports 17,21,30,33,[40][41][42][43][44][45][46][47][48][49][50][51][52] (see Table I). The detection sensitivity of CAT and HQ on NanoAu/ Poly(ABSA)/MWCNTs/GCE by us was 16.53 and 17.68 μA•μM -1 •cm -2 respectively, much bigger than those from literature reports.…”
Section: Resultssupporting
confidence: 56%
See 1 more Smart Citation
“…All the linear equations, linear correlation coefficient (R 2 ), and detection limits were listed in Table SI (see in Supplementary Information). The detection limits of CAT and HQ on NanoAu/Poly(ABSA)/MWCNTs/GCE were close or smaller than those from most of literature reports 17,21,30,33,[40][41][42][43][44][45][46][47][48][49][50][51][52] (see Table I). The detection sensitivity of CAT and HQ on NanoAu/ Poly(ABSA)/MWCNTs/GCE by us was 16.53 and 17.68 μA•μM -1 •cm -2 respectively, much bigger than those from literature reports.…”
Section: Resultssupporting
confidence: 56%
“…Chemically modified electrodes based on the modification of active materials on bare electrode can not only seperate CAT and HQ well but also improve their detection sensitivity, which are widely applied to construct electrochemical sensor for determining CAT and HQ simultaneously. [17][18][19] Carbon nanotubes (CNTs) are the nanomaterials with notable tensile strength, elasticity, catalytic property and chemical activity. 20,21 However, for CNTs modified electrode, CNTs are easy to fall off from electrode surface during multiple electrochemical measurements.…”
mentioning
confidence: 99%
“…The AuNPs [34] modified working electrode can provide more electro active sites and faster electron transfer rate, all of which contribute to enhance the sensitivity of the simultaneous determination of Hydroquinone and catechol. It is difficult to simultaneously determine catechol and hydroquinone due to their overlapping peaks at ordinary electrode [35].…”
Section: Electro Active Carbon Nanomaterials and Its High Surface Densitymentioning
confidence: 99%
“…1,2 HQ, essential in industries like dyes, pharmaceuticals, cosmetics, and rubber, is environmentally toxic and may enter the human body. 3,4 Multiple methods like flame atomic absorption spectrometry (FAAS), 5 UV-vis spectrophotometry, [6][7][8] fluorescence (FL) methods, [9][10][11][12] chemiluminescence (CL) methods, [13][14][15] and electrochemical detection (ED) 16,17 are available for Co and HQ analysis. The pursuit of more accurate and sensitive techniques continues.…”
Section: Introductionmentioning
confidence: 99%