2018
DOI: 10.1186/s13007-018-0329-0
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous untargeted and targeted metabolomics profiling of underivatized primary metabolites in sulfur-deficient barley by ultra-high performance liquid chromatography-quadrupole/time-of-flight mass spectrometry

Abstract: BackgroundMetabolomics based on mass spectrometry analysis are increasingly applied in diverse scientific domains, notably agronomy and plant biology, in order to understand plants’ behaviors under different stress conditions. In fact, these stress conditions are able to disrupt many biosynthetic pathways that include mainly primary metabolites. Profiling and quantifying primary metabolites remain a challenging task because they are poorly retained in reverse phase columns, due to their high polarity and acid–… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
3
1

Relationship

2
8

Authors

Journals

citations
Cited by 48 publications
(32 citation statements)
references
References 48 publications
0
31
0
Order By: Relevance
“…Data analysis of metabolic and transcriptional profiles. All mass spectral data were imported into Progenesis QI for data processing, then were grouped and exported to Ezinfo for principal component analysis (PCA) 64 . PCA is a very useful statistical method for defining the dimensions of large data sets and identifying significant signals 65 .…”
Section: Methodsmentioning
confidence: 99%
“…Data analysis of metabolic and transcriptional profiles. All mass spectral data were imported into Progenesis QI for data processing, then were grouped and exported to Ezinfo for principal component analysis (PCA) 64 . PCA is a very useful statistical method for defining the dimensions of large data sets and identifying significant signals 65 .…”
Section: Methodsmentioning
confidence: 99%
“…Data treatment, alignment, peak picking, normalization, deconvolution, and multivariate analysis was performed using Progenesis QI software (Nonlinear Dynamics, Newcastle, United Kingdom) and EZinfo 3.0 software (Umetrics AB, Umeå, Sweden). Concentration of all metabolites and amino acids were calculated by external calibration based on analytical standards using TargetLynx TM software (Waters, United States) ( Ghosson et al, 2018 ). Statistical analysis was achieved using MetaboAnalyst ( Xia et al, 2015 ).…”
Section: Methodsmentioning
confidence: 99%
“…The high-resolution mass spectrometer was used as a detector, which allows for the identification and quantification of target molecules with high sensitivity and specificity. Although triple-quadrupole mass spectrometry-based methods are commonly used for quantitation purposes, high-resolution systems, such as quadrupole-time of flight (Q-TOF) MS or quadrupole (Q)-Orbitrap MS, are also successfully used in metabolite determination [ 33 , 34 , 52 ]. They provide excellent mass accuracy (<5 ppm) and thus distinguish between analytes and some background interferences, which are not resolved with low-resolution mass spectrometers.…”
Section: Resultsmentioning
confidence: 99%