1964
DOI: 10.1021/ac60210a028
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Spectrophotometric Determination of Calcium and Magnesium with Chlorophosphonazo III.

Abstract: 15 431 448 20 431 431 acetic acid-chloroform mixture.In almost all cases, 5 ml. of the solvents tested were miscible with 20 ml. of acetic acid-chloroform.Recovery of peroxide was quantitative when as little as 20% by volume of acetic acidchloroform was present in the solvent mixture. It should therefore be possible to determine peroxide groups on polymers and other organic solids if the solution of the material is compatible with the minimum amount of acetic acid-chloroform required for the reaction of the pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

1971
1971
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(16 citation statements)
references
References 30 publications
1
15
0
Order By: Relevance
“…Serum was subjected to calcium and Pi measurements using the automated clinical chemistry analyzer Fuji Dri-chem 4000 (Fujifilm, Tokyo, Japan) based on colometric analysis using the chlorophosphonazo-III and purine nucleoside phosphorylase reactivity, respectively (Ferguson et al, 1964;Hwang et al, 1973). For FGF-23 measurements, mouse sera collected as described above were tested for FGF-23 concentration using an FGF-23 ELISA kit (Kainos Laboratories, Tokyo, Japan).…”
Section: Scanning Electron Microscopy (Sem) and Transmission Electronmentioning
confidence: 99%
“…Serum was subjected to calcium and Pi measurements using the automated clinical chemistry analyzer Fuji Dri-chem 4000 (Fujifilm, Tokyo, Japan) based on colometric analysis using the chlorophosphonazo-III and purine nucleoside phosphorylase reactivity, respectively (Ferguson et al, 1964;Hwang et al, 1973). For FGF-23 measurements, mouse sera collected as described above were tested for FGF-23 concentration using an FGF-23 ELISA kit (Kainos Laboratories, Tokyo, Japan).…”
Section: Scanning Electron Microscopy (Sem) and Transmission Electronmentioning
confidence: 99%
“…Colorimetric methods for detecting plutonium at low concentration, such as complexation with a chromotropic dye such as chlorophosphonazo-III or arsenazo-III lack specificity for oxidation states and are often subject to interferences from other metal ions and electrolyte ions [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…Serum Ct and CEA were analyzed using an automated chemiluminescence immunoassay system (i2000; Abbott Laboratories, Chicago, IL, USA) according to the manufacturer's protocols. The serum CA was detected using the arsenazo III method (8). The tribromoarsenazo was provided by Sigma-Aldrich (St. Louis, MO, USA).…”
Section: Methodsmentioning
confidence: 99%