2020
DOI: 10.1007/s41664-020-00142-z
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Quantification of Five Stereoisomeric Hexoses in Nine Biological Matrices Using Ultrahigh Performance Liquid Chromatography with Tandem Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…Because of the polarity of DNT (logP = −0.55) [17], liquid chromatography-ultraviolet detection (LC-UV) [18] and liquid chromatography-mass spectrometry (LC-MS) [19][20][21] are widely used techniques. In addition to the detection method, calibrants are also indispensable for accurate results.…”
Section: Introductionmentioning
confidence: 99%
“…Because of the polarity of DNT (logP = −0.55) [17], liquid chromatography-ultraviolet detection (LC-UV) [18] and liquid chromatography-mass spectrometry (LC-MS) [19][20][21] are widely used techniques. In addition to the detection method, calibrants are also indispensable for accurate results.…”
Section: Introductionmentioning
confidence: 99%
“…Liquid chromatography tandem mass spectrometry (LC-MS/MS) is undoubtedly a powerful tool for trace analyte detection due to its strong qualitative and quantitation ability [ 15 , 16 ]. By monitoring characteristic ion pairs of each analyte, LC-MS/MS allows one to detect targeted molecules with high specificity and sensitivity even in complex matrices [ 17 , 18 , 19 ]. Therefore, the use of the LC-MS/MS technique could eliminate the inherent drawbacks of FAA derivatization.…”
Section: Introductionmentioning
confidence: 99%
“…The Michael addition uses 1-phenyl-3-methyl-5-pyrazolone (PMP) as a derivatization reagent for the analysis of reducing monosaccharides. This method requires large amounts of PMP, and removal of the excess PMP by extractions with chloroform water could lead to the loss of derivatives during this process. Hydrazone formation-based derivatization with 3-nitrophenylhydrazine was applied to determine monosaccharides in red wine and biological matrices . In these studies, the acidic monosaccharides that widely exist in a variety of organisms were not included.…”
mentioning
confidence: 99%
“…Hydrazone formation-based derivatization with 3-nitrophenylhydrazine was applied to determine monosaccharides in red wine 22 and biological matrices. 23 In these studies, the acidic monosaccharides that widely exist in a variety of organisms were not included. Reductive amination introduces a group at the reducing terminus of carbohydrates using anthranilic acid 24 or 2aminobenzamide.…”
mentioning
confidence: 99%