Simultaneous quantification of five proteins and seven additives in dairy products with a heart-cutting two-dimensional liquid chromatography method

Abstract: A heart-cutting two-dimensional high-performance liquid chromatography method was developed to simultaneously quantify five major proteins and seven food additives (maltol, ethyl maltol, vanillin, ethyl vanillin, benzoic acid, sorbic acid, and saccharin sodium) in milk and milk powders. In this two-dimensional system, a Venusil XBP-C4 column was selected in the first dimension for protein separation, and a Hypersil ODS-2 C18 column was employed in the second dimension for additive separation; a two-position, s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…The better peak shape and baseline could be obtained using 10 m m ammonium phosphate buffer. Because a short switching time in the 1 D column could improve the shape of the peaks in the second‐dimensional chromatogram (Hou et al, ), the corresponding mobile phases of first‐dimensional separation were ACN–ammonium phosphate buffer (20:80, v/v) to elute the VPA quickly. Under these conditions, VPA could be completely transferred within 2.02–3.00 min from 1 D column to the middle column.…”
Section: Resultsmentioning
confidence: 99%
“…The better peak shape and baseline could be obtained using 10 m m ammonium phosphate buffer. Because a short switching time in the 1 D column could improve the shape of the peaks in the second‐dimensional chromatogram (Hou et al, ), the corresponding mobile phases of first‐dimensional separation were ACN–ammonium phosphate buffer (20:80, v/v) to elute the VPA quickly. Under these conditions, VPA could be completely transferred within 2.02–3.00 min from 1 D column to the middle column.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, a fully automated method was developed with the advantage of performing the whole process in less than 35 min and without requiring an additional sample preparation procedure thanks to the on‐line clean‐up effect. Other applications have also focused on the analysis of food additives in milk (Hou, Sun et al, 2015), milk powder (Ma, Zhang et al, 2014) and yogurt (Hou, Ma et al, 2015) by LC–LC methodologies. These latter studies share the use of trapping columns in the interface between 1 D and 2 D. The selection of the trapping columns must be carefully considered since they must be more retentive than the 1 D column but not too much to avoid carry over and to elute the analytes with the 2 D solvent.…”
Section: Application Of 2d‐lc–ms To Food Analysismentioning
confidence: 99%
“…The figures in this chapter were taken from my previously published papers [6,23], and I have got the permission to reuse it.…”
Section: Acknowledgementsmentioning
confidence: 99%