2011
DOI: 10.1016/j.talanta.2010.10.046
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants in liquid cleaners and disinfectants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…( 2) and ( 4)) were stable up to 60 -70 °C, K S varied in the range from 2 × 10 -8 to 5 × 10 −10 M. The main electrochemical parameters were also determined. They were the linearity ranges of the electrode function (5 × 10 -5 (5 × 10 -6 ) -1 × 10 -2 (1 × 10 -3 ) M) and the slopes of the electrode functions (47 -59 mV decade -1 ), response time (60 -90 s), drift potential (2 -3 mV in a day), shelf life (3 -4 months), limits of detection of tetramethylammonium salts (1 × 10 -5 -4 × 10 -7 M) [71].…”
Section: Ion-selective Electrodes For the Determination Of Quaternary...mentioning
confidence: 99%
“…( 2) and ( 4)) were stable up to 60 -70 °C, K S varied in the range from 2 × 10 -8 to 5 × 10 −10 M. The main electrochemical parameters were also determined. They were the linearity ranges of the electrode function (5 × 10 -5 (5 × 10 -6 ) -1 × 10 -2 (1 × 10 -3 ) M) and the slopes of the electrode functions (47 -59 mV decade -1 ), response time (60 -90 s), drift potential (2 -3 mV in a day), shelf life (3 -4 months), limits of detection of tetramethylammonium salts (1 × 10 -5 -4 × 10 -7 M) [71].…”
Section: Ion-selective Electrodes For the Determination Of Quaternary...mentioning
confidence: 99%
“…Although various cationic emulsifiers with high corrosion resistance have been developed, the toxic cationic emulsifiers used for preparing the WEP emulsions pose serious threats to human health and natural environments. 13,14 By contrast, the nonionic emulsifiers are more environmentally friendly and exhibit high corrosion r e s i s t a n c e . F o r i n s t a n c e , t h e n o n i o n i c p o l y -(hydroxyaminoethers) emulsifier significantly improves the corrosion resistance of WEP coatings, which can withstand 24 h of salt spray test without corrosion.…”
Section: Introductionmentioning
confidence: 99%
“…[21] Thus, several potentiometric ion selective sensors have introduced for the determination of cationic surfactant determination up to now. [4,[22][23][24][25][26][27][28] Many surfactant sensors typically consist of a liquid membrane-type sensor, including an ionophore, high molecular weight PVC, and a plasticizer. [29,30] The ionophore serves as the sensing material and is generally responsible for selective interaction with the surfactant counter-ion and for the formation of the ion-pair.…”
Section: Introductionmentioning
confidence: 99%
“…At this point, because of their remarkable properties, such as high selectivity, broad linear operational range, low limit of detection, high accuracy and precision, short analysis time, simple design, low price, no harm to the measured specimen, no pre‐processing stages, and determination even in colored and sedimentary solutions, potentiometric ion‐selective electrodes/sensors appear as an alternative method to most of the above‐mentioned detection methods for cationic surfactant determination [21] . Thus, several potentiometric ion selective sensors have introduced for the determination of cationic surfactant determination up to now [4,22–28] …”
Section: Introductionmentioning
confidence: 99%