Laser Techniques for Fluid Mechanics 2002
DOI: 10.1007/978-3-662-08263-8_15
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of velocity and particle size profiles with the reference beam technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(12 citation statements)
references
References 11 publications
0
12
0
Order By: Relevance
“…Furthermore, the acquisition of two widely separated burst signals requires a large memory capacity for the signal processing technique. An alternative reference Doppler technique for the localization of the particle trajectory has been demonstrated with the evaluation of the spatial frequency in the interference pattern of the reference laser beam [15]. The position is determined by the phase difference of two detected burst signals.…”
Section: -Profile Sensormentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, the acquisition of two widely separated burst signals requires a large memory capacity for the signal processing technique. An alternative reference Doppler technique for the localization of the particle trajectory has been demonstrated with the evaluation of the spatial frequency in the interference pattern of the reference laser beam [15]. The position is determined by the phase difference of two detected burst signals.…”
Section: -Profile Sensormentioning
confidence: 99%
“…The position is determined by the phase difference of two detected burst signals. The spatial resolution was estimated to be about 30 µm for a measurement range of 10mm [15]. However, both arrangements require forward-scattered light [12,15], which usually requires detached receiving optics, implying a complicated adjustment.…”
Section: -Profile Sensormentioning
confidence: 99%
See 1 more Smart Citation
“…This makes it possible to resolve spatial measurands along optical fibres [174]. Inside the measurement volume, the position as well as the velocity of individual tracers is measured by the profile sensor [25,160,161,172,173,[175][176][177]. The velocity profile of the flow is sampled by tracers.…”
Section: Highly Resolved Ldv Measurementsmentioning
confidence: 99%
“…Highly resolved analysis of two-phase flows, e.g. of sprays, can be accomplished by means of a profile PDA sensor [177].…”
Section: Highly Resolved Ldv Measurementsmentioning
confidence: 99%