2019
DOI: 10.1016/j.optcom.2019.07.014
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of temperature and humidity based on FBG-FP cavity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Δn is the refractive index modulation depth, neff is the core effective reflective index, λ is the wavelength in air, Λ is the grating period and L is the grating length. According to Fresnel reflection formula, the reflectivity 𝑅2 of the fiber end face can be expressed as [6] :…”
Section: Sensing Mechanismmentioning
confidence: 99%
See 1 more Smart Citation
“…Δn is the refractive index modulation depth, neff is the core effective reflective index, λ is the wavelength in air, Λ is the grating period and L is the grating length. According to Fresnel reflection formula, the reflectivity 𝑅2 of the fiber end face can be expressed as [6] :…”
Section: Sensing Mechanismmentioning
confidence: 99%
“…( 2), the reflectivity R2 is calculated to be about 4% in case of n and n0 are 1.449 and 1, respectively. Hence, the reflectivity RFP of the FBG-FP cavity sensor is written as [6] :…”
Section: Sensing Mechanismmentioning
confidence: 99%
“…However, the accuracy of the measurement made as a result will be significantly affected by the likely non-overlapping locations of the two sensors used, especially in the case of the dramatic changes that are seen in space applications, for example, in temperature and humidity measurement. The second scheme utilizes a sensor using a combination of wavelength and intensity demodulation methods [11]- [13]. While intensity demodulation-based sensors are usually inconvenient to use (in the need for sensor multiplexing) and to consider the disturbance of the light source as well as the environment on the result of the measurement, and thus an additional photodetector may be required to compensate for any optical power fluctuation that occurs in such a scheme.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the RH sensing makes sense only if the temperature information is provided at the same time. In order to compensate temperature 2 > REPLACE THIS LINE WITH YOUR MANUSCRIPT ID NUMBER (DOUBLE-CLICK HERE TO EDIT) < cross sensitivity and detect temperature information, many hybrid structures have been proposed, such as FBG cascaded with FP cavity [19], FBG cascaded with up-tapered MZI [20], and FBG cascaded with tapered multi-mode fiber [21]. In order to adapt to the monitoring of a narrower environment, such as a microbial culture container, we have further compressed the size of the humidity sensor element.…”
Section: Introductionmentioning