Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
1996
DOI: 10.1109/23.556855
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous macro and micro dosimetry with MOSFETs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
2

Year Published

1998
1998
2023
2023

Publication Types

Select...
4
3
1

Relationship

2
6

Authors

Journals

citations
Cited by 41 publications
(28 citation statements)
references
References 16 publications
0
25
0
2
Order By: Relevance
“…Boron may be easily introduced by using p doped Si arrays as proposed by Rosenfeld. 7 The introduction of nitrogen into the body of a silicon diode is a much more difficult proposition. Nitrogen concentrations required for an acceptable probability of nitrogen capture are too high for maintaining device operation.…”
Section: B Results: Geometry Case 1-ion Generation In Rpp Volumes Wimentioning
confidence: 99%
See 2 more Smart Citations
“…Boron may be easily introduced by using p doped Si arrays as proposed by Rosenfeld. 7 The introduction of nitrogen into the body of a silicon diode is a much more difficult proposition. Nitrogen concentrations required for an acceptable probability of nitrogen capture are too high for maintaining device operation.…”
Section: B Results: Geometry Case 1-ion Generation In Rpp Volumes Wimentioning
confidence: 99%
“…7 This paper demonstrates that extensive study of charge collection in micron sized silicon volumes may lead to the creation of a new class of microdosimeters for high LET radiation fields. A tissue equivalence correction method for BNCT has been determined but further work is required to investigate the tissue equivalence of silicon microdosimeters in other high LET environments such as heavy ion, fast neutron and proton therapy modalities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, a silicon detector of a large area with 7 microns thickness was used. A new approach for silicon microdosimetry based on arrays of silicon SVs (pn-junctions) was proposed by McNulty and Roth [7] for separation of gamma and neutron fields (no microdosimetric spectras was produced) and later SOI microdosimeter was developed and applied to hadron therapy by Rosenfeld [11].…”
Section: Solid State Microdosimetrymentioning
confidence: 99%
“…Silicon microdosimetry was initially developed in the space radiation effects community [8] and was subsequently applied to conventional microdosimetry studies in hadron therapy applications [9]. A prototype silicon microdosimeter was developed which consists of an array of microscopic pn junctions fabricated on varying thicknesses of silicon-on-insulator (SOI) wafers.…”
mentioning