2016
DOI: 10.1186/s13014-016-0687-6
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study

Abstract: BackgroundThe aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer.MethodsAn Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modula… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
14
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(16 citation statements)
references
References 34 publications
(42 reference statements)
2
14
0
Order By: Relevance
“…The SIB approach was discussed at various levels in [ 19 , 21 , 23 , 25 , 29 , 38 , 47 , 48 , 50 , 63 , 67 , 70 ]. Altered patient positioning and bilateral breast : …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The SIB approach was discussed at various levels in [ 19 , 21 , 23 , 25 , 29 , 38 , 47 , 48 , 50 , 63 , 67 , 70 ]. Altered patient positioning and bilateral breast : …”
Section: Resultsmentioning
confidence: 99%
“…The use of high intensity photon beams was addressed in 6 studies [ 21 , 25 , 40 , 47 , 61 , 62 ] plus the two clinical reports from the Humanitas Cancer Center group [ 11 , 12 ]. The treatment of the whole breast or of the chest wall, as well as the use of conventional or of SIB fractionation schemes were appraised.…”
Section: Resultsmentioning
confidence: 99%
“…There is no standard technique for SIB in WBI after BCS, because of conflicting results due to different RT techniques, treatment planning systems, and dose constraints for OARs used in these studies. Maier et al (25) have evaluated IMRT, VMAT, and tangential arc VMAC using Monaco treatment planning for right-sided BC patients using SIB technique. The authors found that best target coverage and homogeneity was observed with VMAT, and lowest doses to the contralateral lung and breast were observed with tangential arc VMAT.…”
Section: Discussionmentioning
confidence: 99%
“…Michalski et al (12) have compared HT, IMRT, and 3D-CRT for left-sided breast tumors with SIB technique, and found that HT offered superior target-volume doses and lower doses to ipsilateral lung and heart, compared to 3D-CRT and IMRT. In dosimetric studies with more conformal techniques, VMAT (16,25) and HT (11,12) provide better target-volume coverage and lower lung and heart doses. In the current study comparing VMAT and HT technologies with the SIB technique, we found that HT had better target-volume coverage and provided lower doses to contralateral breast and lung compared to VMAT.…”
Section: Discussionmentioning
confidence: 99%
“…The flatness filter has been described as the main source of photon scatter in the treatment head [11]. Additional peripheral dose resulting from this contribution has been confirmed in some publications referring to other entities [12][13][14][15][16][17][18] and increases the risk for secondary malignancies. Pituitary adenomas represent about 10% of all intracranial tumors [19].…”
Section: Introductionmentioning
confidence: 85%