2004
DOI: 10.1016/j.ab.2004.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous fluorometric measurement of histamine and tele-methylhistamine levels in rodent brain by high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 29 publications
0
10
0
Order By: Relevance
“…The method was based on post‐column o ‐phthalaldehyde/β‐mercaptoethanol derivatization as described in detail in Miyamoto et al . (). The supernatants of precipitated samples collected as described above were neutralized with 10 volumes of 0.4 m borate buffer.…”
Section: Methodsmentioning
confidence: 97%
See 1 more Smart Citation
“…The method was based on post‐column o ‐phthalaldehyde/β‐mercaptoethanol derivatization as described in detail in Miyamoto et al . (). The supernatants of precipitated samples collected as described above were neutralized with 10 volumes of 0.4 m borate buffer.…”
Section: Methodsmentioning
confidence: 97%
“…The assay used here was a combination of methods for the simultaneous determination of histamine and 1‐methylhistamine levels (Miyamoto et al ., ), HDC activity (Niimi et al ., ), and HNMT activity (Scott et al ., ). The animals (36 male 8‐week‐old C57BL/6J mice and 30 male 8‐week‐old CBA/J mice) were kept in groups of three (100 lux at the cage bottom) for 2 weeks before the experiment.…”
Section: Methodsmentioning
confidence: 99%
“…Mice were dosed with compounds between 0900 and 1400 hours and killed by decapitation at 4 h after administration. Brains were quickly frozen in liquid nitrogen, and histamine, t-MH, and other neurotransmitters were measured as reported (43,44).…”
Section: Methodsmentioning
confidence: 99%
“…The substances were separated using a cation exchange column (Eicopak SC-5ODS; Eicom Corp., Kyoto, Japan) equipped with a guard column (Prepaset CA-ODS; Eicom), and measured by the column switching o-phthalaldehyde (OPA) post-column fluorescence derivation method with excitation and fluorescence wavelengths of 335 and 450 nm, respectively (27). The mobile phase, 0.1 mol/L acetate buffer-methanol solution (91 : 9, v/v) containing 220 mg/L sodium 1-octansulfonate, was passed at a flow rate of 0.5 mL/min.…”
Section: Y-maze Spontaneous Alternation Behavior Testmentioning
confidence: 99%