2019
DOI: 10.1016/j.synthmet.2019.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous electrochemical detection of hydroquinone and catechol using poly(3,4-ethylenedioxythiophene)/reduced graphene oxide/manganese dioxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“…Previous works have reported utilizing a very high concentration of the analytes (0.5 mM HQ and CT at 0.1 M PBS pH 7.0) to better understand the selectivity of the proposed sensor towards HQ and CT in the presence of interfering species. [ 63–65 ] Some possible common interferent [ 49,66 ] such as K + , Na + , Zn 2+ , Mg 2+ , NH 4 + , SO 4 2– , Cl – , NO 3 – , and CO 3 2– with 10‐fold higher concentration compared to HQ and CT were added to the mixture. The current responses of HQ and CT were found nearly constant in the presence of each interfering ion.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous works have reported utilizing a very high concentration of the analytes (0.5 mM HQ and CT at 0.1 M PBS pH 7.0) to better understand the selectivity of the proposed sensor towards HQ and CT in the presence of interfering species. [ 63–65 ] Some possible common interferent [ 49,66 ] such as K + , Na + , Zn 2+ , Mg 2+ , NH 4 + , SO 4 2– , Cl – , NO 3 – , and CO 3 2– with 10‐fold higher concentration compared to HQ and CT were added to the mixture. The current responses of HQ and CT were found nearly constant in the presence of each interfering ion.…”
Section: Resultsmentioning
confidence: 99%
“…The stability studies were carried out with high concentrations of HQ and CT based on previous reports. [ 63 ] The high concentration was utilized to determine the stability of the prepared electrodes towards HQ and CT. The RSD was obtained to be 2.12% for HQ and 1.94% for CT, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Due to irreversible agglomeration through π–π stacking and Van der Waals forces in the absence of polymer dispersant or surfactant, the stability of rGO is limited. Therefore, functionalization of rGO is needed to prevent the aggregation of π–π stacking of two sheets [4,53,159,160] . To prevent aggregation, Zheng et al [161] .…”
Section: Simultaneous Detection Of Hq and Ctmentioning
confidence: 99%
“…Polymer incorporation is a commonly used strategy to prevent the aggregation of rGO. Mohanadas and coworkers [53] electrochemically incorporated poly(3,4‐ethylenedioxythiophene) (PEDOT) into rGO sheets and subsequently manganese dioxide (MnO 2 ) on PEDOT/rGO. MnO 2 boosted the electrocatalytic activity of PEDOT/rGO toward HQ and CT.…”
Section: Simultaneous Detection Of Hq and Ctmentioning
confidence: 99%
See 1 more Smart Citation