Simultaneous DSC-FTIR spectroscopy: Comparison of cross-linking kinetics of an epoxy/amine resin system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
24
0
2

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(44 citation statements)
references
References 29 publications
1
24
0
2
Order By: Relevance
“…The epoxy conversion can also be measured directly by structural changes using spectroscopic methods like near-infrared (NIR) [4,[22][23][24][25], mid-infrared (MIR) [26][27][28][29] or Raman [30][31][32] spectroscopy. In the NIR region bands are often difficult to evaluate due to mode coupling and overtones, hence MIR spectroscopy is often preferred to analyse chemical composition.…”
Section: Introductionmentioning
confidence: 99%
“…The epoxy conversion can also be measured directly by structural changes using spectroscopic methods like near-infrared (NIR) [4,[22][23][24][25], mid-infrared (MIR) [26][27][28][29] or Raman [30][31][32] spectroscopy. In the NIR region bands are often difficult to evaluate due to mode coupling and overtones, hence MIR spectroscopy is often preferred to analyse chemical composition.…”
Section: Introductionmentioning
confidence: 99%
“…The discrepancy between the measured and predicted rate of depletion is generally attributed to: (i) a change in the reaction mechanism from chemical-controlled to diffusion-controlled reactions towards the latter stages [10]; (ii) the fact that the rate constants for the primary and secondary amine reaction rates may be different (a single rate Table 2 Rate constant k for the EPO-TEK ® 310M resin system when using transmission and evanescent wave Fourier transform infrared spectroscopy at specified processing temperatures. constant is assumed in the auto-catalytic model) [21]; (iii) the sum of the reaction orders, m and n, being forced to equate to an integer (2 in the current case) in the curve fitting routine; (iv) the observation that when the epoxy conversions are greater than 80%, the signal-to-noise decreases progressively. In contrast to Fig.…”
Section: Discussionmentioning
confidence: 99%
“…In a previous study [21], the authors used ii-demountable 1 mm path length quartz cuvette; iii-SMA connector enabling optical connection to the spectrometer; iv-impregnated E-glass bundle attached to a pair of SMA connectors; v-thermocouple; and vi-purpose-built oven.…”
Section: Cross-linking Kineticsmentioning
confidence: 99%
See 1 more Smart Citation
“…7,8 Such flexibility of FTIR has been employed also for simultaneous measurement with differential scanning calorimetry (DSC). 9,10 In this study, we tried to establish the simultaneous SANS/ FTIR measurement protocol. For this purpose, a device consisting of a portable FTIR spectrometer and an optical system, which allows a sample to be irradiated with neutron and infrared beams simultaneously, was developed and installed on a smallangle neutron diffractometer.…”
mentioning