2011
DOI: 10.1016/j.jchromb.2011.09.021
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of timolol maleate, rosuvastatin calcium and diclofenac sodium in pharmaceuticals and physiological fluids using HPLC-UV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(32 citation statements)
references
References 27 publications
0
27
0
Order By: Relevance
“…Finally, using ion paring LLE, extraction efficacy of rosuvastatin in ethyl acetate was improved from around 10% to more than 50%. A somewhat unusual LLE method for determination of timolol maleate, rosuvastatin and diclofenac in human plasma and aqueous humor from the bovine eyes was proposed [81]. The mobile phase, consisted of acetonitrile and 0.2% triethylamine, was used as extraction solvent.…”
Section: Sample Preparationmentioning
confidence: 99%
See 2 more Smart Citations
“…Finally, using ion paring LLE, extraction efficacy of rosuvastatin in ethyl acetate was improved from around 10% to more than 50%. A somewhat unusual LLE method for determination of timolol maleate, rosuvastatin and diclofenac in human plasma and aqueous humor from the bovine eyes was proposed [81]. The mobile phase, consisted of acetonitrile and 0.2% triethylamine, was used as extraction solvent.…”
Section: Sample Preparationmentioning
confidence: 99%
“…Their typical plasma concentrations are in ng/mL levels. However, several sensitive LC/DAD methods for determination of pravastatin [31], atorvastatin [71], lovastatin [73], rosuvastatin [81], and atorvastatin with rosuvastatin [90] have been developed with limit of quantification (LOQ) in range of 1 -10 ng/mL. Less sensitive LC/DAD method for quantification of lovastatin in human plasma was developed [91].…”
Section: High Performance Liquid Chromatographymentioning
confidence: 99%
See 1 more Smart Citation
“…11,12,26,27 The A solvent was acetonitrile and B solvent was 50 mM acetate buffer (1/1), (v/v) pH 3.1. The column temperature was stable at 25°C.…”
Section: Ultra Performance Liquid Chromatography Assay Methods and Valmentioning
confidence: 99%
“…In this work, the HPLC analysis was performed in isocratic mode on a reverse phase Hypersil BDS C 18 column (5 μm, 250 mm × 4.6 mm i.d., Thermo Scientific, IL, USA). The flow rate and column temperature were set at 0.8 ml/min and 20°C, respectively, and the peaks were detected at a wavelength of 275 nm [17].…”
Section: In Vivo Pharmacokinetic Studymentioning
confidence: 99%