1999
DOI: 10.2116/analsci.15.575
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Rhodium and Iridium Using Derivative Spectrophotometry after Preconcentration of Their 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol Chelates onto Microcrystalline Naphthalene

Abstract: The economy and efficiency of the analytical procedure for the separation and determination of precious metals, such as rhodium and iridium in geological samples and related materials, are still a challenge to the analyst. Because of their low concentration levels in natural sources, a necessary first step in any analytical procedure needs to be the preconcentration of these elements. The most common and well-documented concentration-cum-separation technique is liquid-liquid extraction. However, this technique… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…As can be seen the LOD of the proposed IP-DLLME-FAAS method, with a sample volume of only 10. 0 mL, is lower than some of the previously proposed methods 6,10,11,[16][17][18] and higher than some of the other methods. 3,19,20 While, the extraction time is very shorter than all of the mention methods because no need any Rh-ligand complex formation, which indicates the fact that IP-DLLME is a very sensitive and rapid technique that can be used for the pre-concentration and determination of Rh(III) from real samples.…”
Section: Comparison Of Ip-dllme-faas With Other Methodsmentioning
confidence: 66%
See 2 more Smart Citations
“…As can be seen the LOD of the proposed IP-DLLME-FAAS method, with a sample volume of only 10. 0 mL, is lower than some of the previously proposed methods 6,10,11,[16][17][18] and higher than some of the other methods. 3,19,20 While, the extraction time is very shorter than all of the mention methods because no need any Rh-ligand complex formation, which indicates the fact that IP-DLLME is a very sensitive and rapid technique that can be used for the pre-concentration and determination of Rh(III) from real samples.…”
Section: Comparison Of Ip-dllme-faas With Other Methodsmentioning
confidence: 66%
“…In Table 3 are compared the main analytical characteristics (i.e., LR, ER and LOD) of the proposed IP-DLLME-FAAS method for the determination of Rh(III) with those of some of the best previously reported methods for this purpose including SPEspectrophotometry, 6,11 FIA-FAAS, where Rh (III) is adsorbed on a cross-linked polystyrene sorbent, 16 ETAAS after separation, using Dowex 1×8-200, 17 differential pulse polarography, after preconcentration onto microcrystalline naphthalene, 18 laser induced-thermal lens spectrometry after cloud point extraction, 19 FAAS determination after preconcentration onto carbon nanotube, 3 FAAS determination after cloud point extraction 20 and liquid-liquid extraction prior inductively coupled plasma optimal emission spectrometer determination (ICP-OES) 10 . As can be seen the LOD of the proposed IP-DLLME-FAAS method, with a sample volume of only 10.…”
Section: Comparison Of Ip-dllme-faas With Other Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Tetraphenylborate anion has been used as a counter ion in the extraction and adsorption of some cationic metal chelates into molten naphthalene 17 and microcrystalline naphthalene 9 techniques, respectively. It forms a weak ion pair with NH4 + ion in aqueous solution and coprecipitates along with microcrystalline naphthalene when the pH of the solution is above 8.5.…”
Section: Retention Characteristics Of Atpb-naphthalene Adsorbentmentioning
confidence: 99%
“…5 A number of solid-phase extraction (SPE) methods have been reported in the literature which utilizes various materials, such as ion-exchange resin, functionally modified polymers and C18-glass beads as adsorbents. [6][7][8][9] Although, these methods result in better recovery and an excellent preconcentration factor, the slow sorption and desorption process, and a tedious procedure for preparing the adsorbents make these methods troublesome and time-consuming. Therefore, from economy and simplicity point of view, a conventional determination method with an improved analytical procedure, which can match the modern analytical instruments in terms of its specificity and sensitivity, would find many applications in common laboratories.…”
Section: Introductionmentioning
confidence: 99%