2015
DOI: 10.1080/03067319.2015.1046055
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of Ponceau-4R and Allura Red in soft drinks based on the ionic liquid modified expanded graphite paste electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…To address the above-mentioned issues, much effort has been made to develop novel modified electrodes that are capable of efficiently detecting Allura Red based on the oxidation signals. Novel electrochemical sensors based on multiwalled carbon nanotube (MWCNT) [28,29], ionic liquids [30], cobalt oxide [31], and cobalt complex [32] modified electrodes have shown great potentials on the detection of Allura Red, due to their excellent accumulation efficiency and large specific surface area. For example, MWCNT/GCE showed a wide linear response range of 496-4468 µg/L, and it was applied to the analysis of commercial isotonic sports drinks with satisfactory results [28].…”
Section: Introductionmentioning
confidence: 99%
“…To address the above-mentioned issues, much effort has been made to develop novel modified electrodes that are capable of efficiently detecting Allura Red based on the oxidation signals. Novel electrochemical sensors based on multiwalled carbon nanotube (MWCNT) [28,29], ionic liquids [30], cobalt oxide [31], and cobalt complex [32] modified electrodes have shown great potentials on the detection of Allura Red, due to their excellent accumulation efficiency and large specific surface area. For example, MWCNT/GCE showed a wide linear response range of 496-4468 µg/L, and it was applied to the analysis of commercial isotonic sports drinks with satisfactory results [28].…”
Section: Introductionmentioning
confidence: 99%
“…When used excessively, synthetic dyes, especially those containing aromatic rings and azofunctional groups, become potentially toxic to the human body [ 1 , 2 ]. Decomposition products can accumulate and provoke allergic reactions, the development of cancer, and disorders of the gastrointestinal tract, respiratory tract, and central nervous system [ 3 ].…”
Section: Introductionmentioning
confidence: 99%
“…High electrocatalytic activity with regard to Ponceau 4R oxidation was demonstrated by an electrode based on a composite containing solid paraffin and an ionic liquid-modified expanded graphite paste electrode [ 1 ]. In comparison with unmodified electrodes, a 7.5-fold increase in the peak oxidation current of Ponceau 4R was observed on the ionic liquid-modified expanded graphite paste electrode, which can be explained by the sensitizing effect of the ionic liquid.…”
Section: Introductionmentioning
confidence: 99%
“…So far different analytical techniques have been adapted for the determination of Ponceau-4R [PR] and Allura Red [AR], such as spectrophotometry 1,4 high-performance liquid chromatography 5,6 , differential pulse polarography 7 , LC-MS method 8 and electrochemical methods 9,10 . However, these methods are expensive, time consuming, complicated to operate, and requires extensive sample preparations.…”
mentioning
confidence: 99%