2000
DOI: 10.1016/s0731-7085(00)00343-5
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of mecamylamine, nicotine, and cotinine in plasma by gas chromatography-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
36
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(36 citation statements)
references
References 8 publications
0
36
0
Order By: Relevance
“…Prior to each extraction, hexane, butanol, toluene, and water were each passed through a benzenesulfonic acid silica-gel cartridge (United Chemical Technologies), and glassware was heated in a muffle furnace at 500°C for 3 hr to remove background nicotine contamination. The liquid-liquid extraction protocol used for this analysis was adapted from Jacob, Wu, Yu, and Benowitz (2000). To a 0.1-g portion of dust in a centrifuge tube was added an internal standard (40 ng of methyl-d 3 -nicotine) and a 2-ml aqueous solution containing 45% potassium carbonate and 5% edetic acid, followed by sonication for 10 min.…”
Section: Laboratory Analysis Of Nicotinementioning
confidence: 99%
“…Prior to each extraction, hexane, butanol, toluene, and water were each passed through a benzenesulfonic acid silica-gel cartridge (United Chemical Technologies), and glassware was heated in a muffle furnace at 500°C for 3 hr to remove background nicotine contamination. The liquid-liquid extraction protocol used for this analysis was adapted from Jacob, Wu, Yu, and Benowitz (2000). To a 0.1-g portion of dust in a centrifuge tube was added an internal standard (40 ng of methyl-d 3 -nicotine) and a 2-ml aqueous solution containing 45% potassium carbonate and 5% edetic acid, followed by sonication for 10 min.…”
Section: Laboratory Analysis Of Nicotinementioning
confidence: 99%
“…Plasma nicotine levels were measured in duplicate using a gas chromatography-mass spectrometry method described by Jacob and co-workers (Jacob et al, 2000). The nicotine assay sensitivity was 5.0 ng/ml and the intra-and interassay CVs were 4.6 and 11.5%, respectively.…”
Section: Assay Proceduresmentioning
confidence: 99%
“…Plasma nicotine levels were measured in duplicate using a gas chromatography-mass spectrometry method described by Jacob et al (2000). The nicotine assay sensitivity was 1.0 ng/ml and the intra-and interassay CVs were 4.7 and 11.5%, respectively.…”
Section: Assay Proceduresmentioning
confidence: 99%