Simultaneous determination of halogenated contaminants and polycyclic aromatic hydrocarbons: a multi-analyte method applied to filter-feeding edible organisms

Abstract: This study develops and validates a novel analytical approach for the simultaneous determination of 127 polychlorinated biphenyls (PCBs), together with 6 polychlorinated naphthalenes (PCNs) and 16 polycyclic aromatic hydrocarbons (PAHs). PCBs, PCNs, and PAHs were subjected to a unique pretreatment protocol and were simultaneously determined in a single chromatographic run, using GC-MS, in environmental marine samples of mussels and clams. The results of the validation experiments, which were performed on the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 48 publications
1
6
0
1
Order By: Relevance
“…QFFs were broken in small pieces and mixed with anhydrous sodium sulfate, diatomaceous earth and Ottawa sand (Sigma-Aldrich Co., Applied Separation Inc.). The operative conditions were previously optimized for enhanced extraction efficiency and to minimize the amount of solvent required [40,41]. The extractions were performed at 100°C and 100 bar, with 3 static cycles of 7 min each.…”
Section: Extractionmentioning
confidence: 99%
See 1 more Smart Citation
“…QFFs were broken in small pieces and mixed with anhydrous sodium sulfate, diatomaceous earth and Ottawa sand (Sigma-Aldrich Co., Applied Separation Inc.). The operative conditions were previously optimized for enhanced extraction efficiency and to minimize the amount of solvent required [40,41]. The extractions were performed at 100°C and 100 bar, with 3 static cycles of 7 min each.…”
Section: Extractionmentioning
confidence: 99%
“…The eluates were collected as one single fraction. Purified samples were reduced to 100 μL under a gentle nitrogen flow at 23°C and spiked with a known amount of the recovery standard solution (1 13 C-labelled PAHs at ng μL −1 , 2 13 Clabelled PCBs at pg μL −1 and 2 13 C-labelled PCDD/Fs at 20 pg μL −1 ; CIL Inc.) according to the method fully described in Pizzini et al [41,47].…”
Section: Clean-upmentioning
confidence: 99%
“…In general, PCNs and ClPAHs have been analyzed by highresolution gas chromatography (HRGC)-high resolution mass spectrometry (HRMS) and gas chromatography (GC)-mass spectrometry (MS). PCNs have been commonly detected by HRGC-HRMS or GC-MS-MS combined with electron ionization (EI) and separated with a nonpolar fused-silica capillary column such as an Agilent DB-5 column (60 m × 0.25mm inner diameter, 0.25-μm film thickness) [2,[7][8][9]. They have also been analyzed with a GC-MS system equipped with an electron capture negative ion detector and a nonpolar column.…”
Section: Simultaneous Detection Of Chlorinated Polycyclic Aromatic Hydrocarbons With Polycyclic Aromatic Hydrocarbons By Gas Chromatograpmentioning
confidence: 99%
“…Even thought Liquid Chromatography coupled to Mass Spectrometry (LC/MS) offers similar advantages, it does not supply a specific interface appropriate for the separation of all the PHAs at the same time [28,31].…”
Section: Introductionmentioning