Simultaneous determination of fifteen multiclass organic pollutants in human saliva and serum by liquid chromatography–tandem ultraviolet/fluorescence detection: A validated method

Abstract: A quick and inexpensive validated method, based on sample treatment by liquidliquid microextraction followed by liquid chromatography (LC) coupled with ultraviolet tandem fluorescence detection is proposed for the determination of 15 multiclass pollutants both in serum and in saliva, as a simple and easy to draw matrix. The method was set up and validated according to European guidelines. The compounds of interest include some endocrine-disrupting chemicals (i.e. bisphenol A, bisphenol B, bisphenol E, bispheno… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 46 publications
0
9
0
Order By: Relevance
“…The EC 50 -values estimated from these curves ranged from 0.79 to 14.87 µM and the lowest effective dose values (EC 05 ) ranged from 0.18 to 2.37 µM ( Table 2). In the literature, we could only identify human plasma or serum levels for BPAF, BADGE, and BPB out of the six "positive hit" bisphenols (49)(50)(51)(52)(53). A reported maximal human serum concentration of BADGE (3.45 µM) (50) is above the EC 05 estimated in our study (1.82 µM), whereas the reported maximal human serum levels of BPAF (0.05 µM) (50) and BPB (0.59 µM) (50) are below the estimated EC 05 -values of 0.36 µM for BPAF and 2.37 µM for BPB.…”
Section: Discussionmentioning
confidence: 99%
“…The EC 50 -values estimated from these curves ranged from 0.79 to 14.87 µM and the lowest effective dose values (EC 05 ) ranged from 0.18 to 2.37 µM ( Table 2). In the literature, we could only identify human plasma or serum levels for BPAF, BADGE, and BPB out of the six "positive hit" bisphenols (49)(50)(51)(52)(53). A reported maximal human serum concentration of BADGE (3.45 µM) (50) is above the EC 05 estimated in our study (1.82 µM), whereas the reported maximal human serum levels of BPAF (0.05 µM) (50) and BPB (0.59 µM) (50) are below the estimated EC 05 -values of 0.36 µM for BPAF and 2.37 µM for BPB.…”
Section: Discussionmentioning
confidence: 99%
“…These results indicate that this analytical method provides a reliable response regardless of the concentrations utilized. This is straightforward given that the biological matrices studied in [38] are much more complex than the waters assayed in this work. After running of each sample in triplicate, methanol injections did not show carryover.…”
Section: Methods Validationmentioning
confidence: 99%
“…Standard calibration curves covered the range indicated in Table 2 and had squared correlation coefficients ( r 2 ) greater than 0.95. The separation and detection of the selected EDCs were accomplished according to an already published method (Russo, Barbato, et al, 2019). All mobile phases were filtered through nylon filters 0.45 μm in pore diameter (Millipore, Burlington, MA USA).…”
Section: Methodsmentioning
confidence: 99%
“…A systematic QA/QC protocol was adopted to monitor the analysis of chemicals under investigation, including linearity, retention time, limits of detection (LOD) and quantification (LOQ), and recovery. For every batch of samples, a procedural blank and spike sample consisting of all reagents was run to check for interference and cross‐contamination (Russo, Barbato, et al, 2019). The Limit of detection (LOD) indicates method's sensitivity, and it is the lowest concentration, at which the respective compound is just measurable.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation