Advances in High-Pressure Technology for Geophysical Applications 2005
DOI: 10.1016/b978-044451979-5.50006-5
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of elastic and structural properties under simulated mantle conditions using multi-anvil device MAX80

Abstract: An ultrasonic interferometry high-pressure set-up for elastic wave velocity measurements under simulated Earth's mantle conditions has been developed. A DIA-type multi-anvil apparatus MAX80 permanently located at HASYLAB, Hamburg, Germany for X-ray diffraction (XRD) under in situ condition was equipped for simultaneous ultrasonic measurements. Two of the six anvils were equipped with lithium niobate P-and S-wave transducers of 33.3 MHz natural frequency. The pressure and temperature limits of the high-pressure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 58 publications
(43 reference statements)
0
3
0
Order By: Relevance
“…X‐ray diffraction data were collected using a solid state Germanium detector analyzed by a multichannel analyzer (MCA). Techniques of high‐pressure ultrasonic interferometry have been discussed in detail in previous studies [e.g., Liebermann and Li , 1998; Kung et al , 2002; Li et al , 2004; Mueller et al , 2005]. Briefly, the sample was surrounded by NaCl+BN on its side and bottom surface to provide pseudohydrostatic stress conditions; it was then placed inside a cylindrical graphite heater located in the middle of the pressure medium made of precompressed Boron epoxy cube (6.15mm edge length).…”
Section: Experimental Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…X‐ray diffraction data were collected using a solid state Germanium detector analyzed by a multichannel analyzer (MCA). Techniques of high‐pressure ultrasonic interferometry have been discussed in detail in previous studies [e.g., Liebermann and Li , 1998; Kung et al , 2002; Li et al , 2004; Mueller et al , 2005]. Briefly, the sample was surrounded by NaCl+BN on its side and bottom surface to provide pseudohydrostatic stress conditions; it was then placed inside a cylindrical graphite heater located in the middle of the pressure medium made of precompressed Boron epoxy cube (6.15mm edge length).…”
Section: Experimental Techniquesmentioning
confidence: 99%
“…A dual mode transducer was used to excite and receive P and S waves simultaneously at the same time when X‐ray diffraction spectrum was taken from the sample. A transfer function method was employed to record the acoustic response of the sample assemblage from which the travel time inside the sample is obtained by off‐line analyses [ Li et al , 2002; Mueller et al , 2005]. The distance the elastic wave traveled (i.e., the length of the sample) was directly monitored by an X radiographic imaging system which has been described in detail elsewhere [e.g., Li et al , 2004; Kung et al , 2002].…”
Section: Experimental Techniquesmentioning
confidence: 99%
“…The experiments were performed in the single-stage multi-anvil DIA-device MAX80 installed at beamline F2.1 at DESY / HASYLAB, Hamburg; Germany (Mueller et al, 2005a(Mueller et al, , b, 2006(Mueller et al, , 2007. The apparatus is made up of a 2500 N hydraulic ram with two load frames driving four reaction bolsters for the lateral anvils ( Fig.…”
Section: Experimental Methodsmentioning
confidence: 99%