2020
DOI: 10.1016/j.jelechem.2019.113741
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of dihydroxybenzene isomers based on gold dendritic/pEDOT electrochemical sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 30 publications
2
12
0
Order By: Relevance
“…The corresponding calibration plots at the applied potential of 0.11 V, 0.21 V and 0.83 V for HQ, CC and KNO 2 were calculated in Figure 6d-f The performances of PPC-900/GCE were compared with other reported HQ and CC electrochemical sensors. As showed in Table 1, [3,27,[63][64][65][66][67][68] The PPC-900/GCE sensor not only exhibited the best linear range, but also possessed excellent limit of detection (LOD) among the selected researches. Meanwhile, the PPC-900/GCE also exhibits the excellent performance of nitrite which compared with other reported sensors are listed in Table 2.…”
Section: Electrochemical Amperometric Determination Of Hq CC and Knomentioning
confidence: 99%
“…The corresponding calibration plots at the applied potential of 0.11 V, 0.21 V and 0.83 V for HQ, CC and KNO 2 were calculated in Figure 6d-f The performances of PPC-900/GCE were compared with other reported HQ and CC electrochemical sensors. As showed in Table 1, [3,27,[63][64][65][66][67][68] The PPC-900/GCE sensor not only exhibited the best linear range, but also possessed excellent limit of detection (LOD) among the selected researches. Meanwhile, the PPC-900/GCE also exhibits the excellent performance of nitrite which compared with other reported sensors are listed in Table 2.…”
Section: Electrochemical Amperometric Determination Of Hq CC and Knomentioning
confidence: 99%
“…4D . Moreover, the slope of E p vs. pH plots (Nernstian slope 58.5 mV pH −1 ) 1 suggests the involvement of equal number of protons and electrons in the redox reaction of DHBIs at the nanosensor surface. The proposed pH dependent electro-oxidation mechanism of DHBIs can be seen in Scheme 1 .…”
Section: Resultsmentioning
confidence: 96%
“…Hydroquinone (HQ), resorcinol (RC), and catechol (CC) are extensively used in tanning, metallurgy, petrochemicals, and cosmetics. [1][2][3][4] Ingestion of these isomeric compounds even at a miniscule level is detrimental owing to their genotoxicity, carcinogenicity and poor degradability. 5 A literature survey revealed the involvement of HQ, CC, and RC in causing headaches, fatigue, acute myeloid leukemia, gastrointestinal tract degeneration, liver malfunction, hemolysis, and DNA damage.…”
Section: Introductionmentioning
confidence: 99%
“…Cheng et al constructed an electrochemical sensor by electrodeposition of dendritic Au nanostructures (DGNs) and electropolymerization of PEDOT consecutively on GCE (PEDOT/DGNs/GCE). The constructed sensor with a dendritic structure, large surface area, and good conductivity, displayed high sensitivity for the detection of dihydroxybenzene isomers 124 with a lower LOD of 9.5 × 10 −7 M for HQ, 1.6 × 10 −6 M for CC, and 1.3 × 10 −6 M for RS. Finally, their sensor showed acceptable results for a successful application to determine dihydroxybenzene in cosmetic samples with satisfactory results.…”
Section: Chlorophenols (Cps)mentioning
confidence: 99%
“…The fabricated electrode successfully detected BPA in milk and water samples with high recovery percentages of 100.9% and 100.5%, respectively. Table S1 in the Supporting Information lists the recent applications of polymer nanocomposites-based electrochemical sensors for the detection of phenolic compounds in different environmental matrices. …”
Section: Polymer Nanocomposites-based Electrochemical Sensors For The...mentioning
confidence: 99%