2018
DOI: 10.1016/j.jchromb.2018.04.028
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
17
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(21 citation statements)
references
References 40 publications
4
17
0
Order By: Relevance
“…The recoveries were 86.8 to 92.5%; these values were similar to those published in other studies (75.7 to 112.0%) using the one-step preparation procedure (23)(24)(25)(26). The variation of ISTD-normalized MF was <5.5%; this was lower than the values estimated by previous studies (6.3 to 10.3%) (23,24). CsA was stable in human whole blood under the tested conditions, which were similar to the conditions used in previous studies (23)(24)(25)(26).…”
Section: Discussionsupporting
confidence: 90%
See 3 more Smart Citations
“…The recoveries were 86.8 to 92.5%; these values were similar to those published in other studies (75.7 to 112.0%) using the one-step preparation procedure (23)(24)(25)(26). The variation of ISTD-normalized MF was <5.5%; this was lower than the values estimated by previous studies (6.3 to 10.3%) (23,24). CsA was stable in human whole blood under the tested conditions, which were similar to the conditions used in previous studies (23)(24)(25)(26).…”
Section: Discussionsupporting
confidence: 90%
“…Furthermore, the LLOQ was 5 ng/ml; this was lower than that reported by other HRMS studies (24.2-28 ng/ml) (5,6), meaning higher sensitivity. The recoveries were 86.8 to 92.5%; these values were similar to those published in other studies (75.7 to 112.0%) using the one-step preparation procedure (23)(24)(25)(26). The variation of ISTD-normalized MF was <5.5%; this was lower than the values estimated by previous studies (6.3 to 10.3%) (23,24).…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…The traditional analytical methods used to measure sirolimus mainly include high-performance liquid chromatography (HPLC) 13,14 and liquid chromatography-mass spectrometry (LC-MS). 11,15,16 Most clinical laboratories use LC-MS/MS as the first choice for drug detection, due to its high sensitivity and specificity.…”
Section: Introductionmentioning
confidence: 99%