2012
DOI: 10.1100/2012/571201
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS

Abstract: Objectives. Cyclosporine A (CyA), tacrolimus (TRL), sirolimus (SIR), and everolimus (RAD) are immunosuppressive drugs frequently used in organ transplantation. Our aim was to confirm a robust sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of CyA, TRL, SIR, and RAD in whole-blood samples.Materials and Methods. We used an integrated online solid-phase extraction-LC-MS/MS system and atmospheri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
24
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(27 citation statements)
references
References 23 publications
3
24
0
Order By: Relevance
“…This was above 98.72% from whole blood samples, values comparable to those reported by other groups [22,31]. Recoveries from homogenate tissue samples were about 85.12±7.71% (table 3).…”
Section: Recovery and Matrix Effectsupporting
confidence: 88%
“…This was above 98.72% from whole blood samples, values comparable to those reported by other groups [22,31]. Recoveries from homogenate tissue samples were about 85.12±7.71% (table 3).…”
Section: Recovery and Matrix Effectsupporting
confidence: 88%
“…Capron et al highlighted that TAC concentrations in peripheral mononuclear blood cells (PBMCs) significantly correlate with both the development and the severity of rejection: lower intra-PCMCs TAC levels were significantly associated to histological rejection and, unlike whole-blood levels, these levels were significantly correlated to the onset of rejection episodes 1 week after transplantation [2]. Several HPLC, LC-MS and LC-MS/MS methods were reported for TAC quantification, but most of these evaluated TAC in whole blood [11][12][13][14]. Capron et al published a method to measure TAC concentrations in PBMCs: quantification of TAC was performed by LC-MS/MS after a cumbersome and time-expensive extraction procedure [15].…”
Section: Introductionmentioning
confidence: 97%
“…Several assays have been developed for the quantification of the drug in biological samples. The most common methods for routine FK506 monitoring are monoclonal antibody-based immunoassays, while liquid chromatography-tandem mass spectrometry (LC-MS) is currently considered as the reference method [4][5][6][7]. LC-MS provides the most specific routine drug measurement, whereas immunoassays show a notable crossreactivity with inactive metabolites [4,8], especially MIII and MV [9].…”
Section: Introductionmentioning