2012
DOI: 10.1155/2012/739891
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Cobalt (II) and Nickel (II) By First Order Derivative Spectrophotometry in Micellar Media

Abstract: A first-derivative spectrophotometry method for the simultaneous determination of Co (II) and Ni (II) with Alizarin Red S in presence of Triton X-100 is described. Measurements were made at the zero-crossing wavelengths at 549.0 nm for Co (II) and 546.0 nm for Ni (II). The linearity is obtained in the range of 0.291- 4.676 μg/ml of Ni (II) and 0.293- 4.124 μg/ml of Co (II) in the presence of each other by using first derivative spectrophotometric method. The possible interfering effects of various ions were st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 0 publications
0
10
0
1
Order By: Relevance
“…Effect of Co 2+ ion concentration on phosphorescence intensity of Mn‐doped ZnS quantum dots. The concentration of Co 2+ ion were: 0, 2.0, 4.0, 6.0, 8.0, 10.0, 15.0, 25.0 and 37.5 µ m . Inset graph is Stern–Volmer plot of the Co(II) concentration dependence of phosphorescence intensity of N ‐acetyl‐ l ‐cysteine‐capped Mn‐doped ZnS quantum dots.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Effect of Co 2+ ion concentration on phosphorescence intensity of Mn‐doped ZnS quantum dots. The concentration of Co 2+ ion were: 0, 2.0, 4.0, 6.0, 8.0, 10.0, 15.0, 25.0 and 37.5 µ m . Inset graph is Stern–Volmer plot of the Co(II) concentration dependence of phosphorescence intensity of N ‐acetyl‐ l ‐cysteine‐capped Mn‐doped ZnS quantum dots.…”
Section: Resultsmentioning
confidence: 99%
“…There has been intense interest in the study of cobalt in environmental and biological samples. Many methods have been used for the determination of Co 2+ ion, including cyclic voltammetry , spectrophotometry , electrothermal atomic absorption spectrometry and fluorimetry . However, these methods suffer from limitations of long extraction time, expensive cost of maintenance, complicated operation and strong interferences from various ions .…”
Section: Introductionmentioning
confidence: 99%
“…Comparando os resultados para determinação de cobalto em preparações farmacêuticas e em outras matrizes, [41][42][43][44][45][46][47][48] observa-se que embora o limite de detecção da metodologia proposta seja mais elevado, a determinação de cobalto nas formulações farmacêuticas estudadas apresentou resultado satisfatório e livre de interferentes. Além disso, as amostras apresentaram a quantidade do analito declarado pelo fabricante estando de acordo com as normas estabelecidas pela ANVISA.…”
Section: Conclusãounclassified
“…Complex reaction between histamine, Co(II) and oxalate has been reported [18] with the complex structure shown (Figure 1), but it has not given a significant change of wavelength and solution color. On the other hand, alizarin red S (ARS) with chemical structure shown ( Figure 2) is well known to form colored complex with metallic and organic compounds such as Al(III) [19], Cu [20], Co and Ni [21], Cu, Co, Ni and cysteine [22], and Ni-histamine [23] with a wide range of ARS solvents. Figure 1.…”
Section: Introductionmentioning
confidence: 99%