2018
DOI: 10.1007/s10337-018-3515-3
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of 20 Antibiotics in Bovine Colostrum Tablet Using UHPLC–MS/MS and SPE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…Due to raised interest in animal-based products, the necessity of analytical methods for the identification of antibiotics in dairy-based products has been of serious concern. A simple and rapid method for simultaneous determination of antibiotics ( n = 20) in BC-based tablets using ultra-high-performance liquid chromatography (UHPLC-MS)–tandem mass spectrometry and solid-phase extraction (SPE) was proposed by Zheng et al [ 59 ]. Based on the experimental results, the authors reported that the use of UHPLC-MS together with hydrophilic–lipophilic balance (HLB) cartridge showed good extraction efficiency, low detection limit, and linearity as compared to the SPE method, which is onerous and required several pretreatments before eluting.…”
Section: Recent Advancements In the Isolation And Identification Of N...mentioning
confidence: 99%
“…Due to raised interest in animal-based products, the necessity of analytical methods for the identification of antibiotics in dairy-based products has been of serious concern. A simple and rapid method for simultaneous determination of antibiotics ( n = 20) in BC-based tablets using ultra-high-performance liquid chromatography (UHPLC-MS)–tandem mass spectrometry and solid-phase extraction (SPE) was proposed by Zheng et al [ 59 ]. Based on the experimental results, the authors reported that the use of UHPLC-MS together with hydrophilic–lipophilic balance (HLB) cartridge showed good extraction efficiency, low detection limit, and linearity as compared to the SPE method, which is onerous and required several pretreatments before eluting.…”
Section: Recent Advancements In the Isolation And Identification Of N...mentioning
confidence: 99%
“…Many instrumental methods have been developed for the detection of KIT and JOS residues, such as high-performance liquid chromatography and liquid chromatography-electrospray mass spectrometry (LC-MS/MS) (Han, Jin, Wu, Shi, & Cui, 2019;Song et al, 2016Song et al, , 2018Zheng et al, 2018). Due to their high accuracy and sensitivity, LC-MS/MS methods have been set as the gold standard for the detection of KIT and JOS.…”
Section: Introductionmentioning
confidence: 99%