1990
DOI: 10.1248/cpb.38.963
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of 2-deoxy-D-glucose and D-glucose in rat serum by high-performance liquid chromatography with post-column fluorescence derivatization.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

1994
1994
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…A range of derivatizing agents has been developed for this purpose p-hydroxybenzoic hydrazide [16,17], 2-cyanoacetamide [18], benzamidine [19,20], meso-1,2-bis(4-methoxyphenyl) ethylenediamine [21], 4-methoxybenzamidine [22], ethanolamine [23]. We chose benzamidine as a derivatization agent because of its high selectivity, reactivity, sensitivity and convenience [21, 24 30].…”
Section: Post-column Derivatizationmentioning
confidence: 99%
“…A range of derivatizing agents has been developed for this purpose p-hydroxybenzoic hydrazide [16,17], 2-cyanoacetamide [18], benzamidine [19,20], meso-1,2-bis(4-methoxyphenyl) ethylenediamine [21], 4-methoxybenzamidine [22], ethanolamine [23]. We chose benzamidine as a derivatization agent because of its high selectivity, reactivity, sensitivity and convenience [21, 24 30].…”
Section: Post-column Derivatizationmentioning
confidence: 99%
“…For 2‐DG quantitation in biological samples, Umegae et al . reported a method for post‐column fluorescent derivatization by reaction with meso ‐1, 2‐ bis (4‐methoxyphenyl)ethylene‐diamine in an alkaline medium after separation on a strong anion exchange column (Umegae et al ., ). Other methods for analyzing the presence of 3 H‐2‐DG in rat muscle using ion exchange chromatography have been reported (Wallis et al ., ); however, the method is only useful for radiolabeled 2‐DG.…”
Section: Introductionmentioning
confidence: 97%
“…Thus, HPLC‐UV is not the method of choice when the analytes are to be quantitated in submicrogram quantities in biologics. Therefore, highly sensitive and reproducible pre‐column and post‐column fluorescence derivatization methods were developed for the quantitation of mono and oligosaccharides in biologics (Anumula, ; Kakita et al ., ; Umegae et al ., ). For 2‐DG quantitation in biological samples, Umegae et al .…”