2010
DOI: 10.1016/j.talanta.2010.01.031
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of 11 antibiotics and their main metabolites from four different groups by reversed-phase high-performance liquid chromatography–diode array–fluorescence (HPLC–DAD–FLD) in human urine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(32 citation statements)
references
References 47 publications
0
31
0
1
Order By: Relevance
“…However, after this time, AMXCs diastereomer were the preferably produced form for AMX‐related compounds at both pH values, suggesting that there are additional contributions involved during the environmental AMX transformation pathway. The absence of AMXC stereoisomers in all real samples (which also are the main metabolites of AMX35, 36) indicate its instability in environmental waters. An internal rearrangement that led to the formation of the diketopiperazine ring is the favored transformation while the ( 5R )‐AMX‐DKP stereoisomer was the only TP detected in surface waters.…”
Section: Resultsmentioning
confidence: 99%
“…However, after this time, AMXCs diastereomer were the preferably produced form for AMX‐related compounds at both pH values, suggesting that there are additional contributions involved during the environmental AMX transformation pathway. The absence of AMXC stereoisomers in all real samples (which also are the main metabolites of AMX35, 36) indicate its instability in environmental waters. An internal rearrangement that led to the formation of the diketopiperazine ring is the favored transformation while the ( 5R )‐AMX‐DKP stereoisomer was the only TP detected in surface waters.…”
Section: Resultsmentioning
confidence: 99%
“…TET was quantified using Agilent 1200 series HPLC equipped with a diode array and fluorescence detector (Fernandez-Torres et al, 2010;Liyanage & Manage, 2014). The injected volume was 20 μL and chromatography was performed at 30 0C.…”
Section: Hplc Quantificationmentioning
confidence: 99%
“…The analytical column Zorbax Eclipse XDB‐C18 (4.6 × 150 mm, id, 5 μm particle size) was used for antibiotic determination. The HPLC method for the separation of sulfamethoxazole and chloramphenicol used a gradient elution program with 0.7 mL/min flow rate. The mobile phase consisted of a mixture of 0.1% formic acid in water and acetonitrile.…”
Section: Methodsmentioning
confidence: 99%