2024
DOI: 10.1016/j.bios.2023.115772
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous detection of C-reactive protein and lipopolysaccharide based on a dual-channel electrochemical biosensor for rapid Gram-typing of bacterial sepsis

Tai-Cheng Lu,
Yuan-Jie Yang,
Yu Zhong
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 44 publications
0
2
0
Order By: Relevance
“…In the work of Zinggeler et al [ 84 ], the UV illumination method was used for the immobilization of CRP antibodies through the process of crosslinking on an electrode substrate; the modified electrode achieved the amperometry technique using a wide range of CRP detection from 10 to 10,000 ng mL −1 . Lu et al [ 85 ] designed a CRP detection electrode using a dual-channel electrode assembled for the simultaneous lipopolysaccharide and CRP detection using a drop-casting approach on the gold electrode ( Figure 7 ). In short, a CRP binding antibody was cast on the Au surface and coated with a premixed CRP sample containing a non-specific interaction inhibition composition of biotin-labeled CRP antibody and bovine serum albumin (BSA).…”
Section: Electrochemical Detection Of Sepsis Biomarkersmentioning
confidence: 99%
See 1 more Smart Citation
“…In the work of Zinggeler et al [ 84 ], the UV illumination method was used for the immobilization of CRP antibodies through the process of crosslinking on an electrode substrate; the modified electrode achieved the amperometry technique using a wide range of CRP detection from 10 to 10,000 ng mL −1 . Lu et al [ 85 ] designed a CRP detection electrode using a dual-channel electrode assembled for the simultaneous lipopolysaccharide and CRP detection using a drop-casting approach on the gold electrode ( Figure 7 ). In short, a CRP binding antibody was cast on the Au surface and coated with a premixed CRP sample containing a non-specific interaction inhibition composition of biotin-labeled CRP antibody and bovine serum albumin (BSA).…”
Section: Electrochemical Detection Of Sepsis Biomarkersmentioning
confidence: 99%
“… Systematic electrode design for CRP and lipopolysaccharide concomitant detection using the TMB and H 2 O 2 electrocatalytic reduction method. Reprinted with permission from [ 85 ]. Copyright (2024) Elsevier.…”
Section: Figurementioning
confidence: 99%