2005
DOI: 10.1248/jhs.51.693
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Chiral Analysis of Methamphetamine and its Metabolites by Capillary Electrophoresis/Mass Spectrometry with Direct Injection of Urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(27 citation statements)
references
References 26 publications
1
26
0
Order By: Relevance
“…Furthermore, the total analysis times could be reduced since off-line sample pretreatment steps such as LLE and SPE, which are usually necessary for urine analysis, were not required. Accordingly, this will be useful when the testing of a large quantity of samples is required within a predetermined period of time, as in doping tests for the Olympic games [52,53], or when the inspection time is limited by the law [54].…”
Section: Application To Urine Samplesmentioning
confidence: 99%
“…Furthermore, the total analysis times could be reduced since off-line sample pretreatment steps such as LLE and SPE, which are usually necessary for urine analysis, were not required. Accordingly, this will be useful when the testing of a large quantity of samples is required within a predetermined period of time, as in doping tests for the Olympic games [52,53], or when the inspection time is limited by the law [54].…”
Section: Application To Urine Samplesmentioning
confidence: 99%
“…On the other hand, analysis times are quite short for this kind of analysis: nine enantiomeric pairs are analysed in 9 min. The same research group had already published some other papers on the same topic in the past, dealing with a lower number of compounds and using the same or very similar dualcyclodextrin selector systems [29][30][31][32][33][34], sometimes using MS detection to apply the method to urine.…”
Section: Amphetaminesmentioning
confidence: 99%
“…They mention as the main drawback of UVdetection its relatively low sensitivity (10 -5 -10 -6 M). Comparatively, the on-line coupling of CE with MS is an attractive technique for the analysis of erythropoietin, because MS detection has the advantage over both UV-Vis and LIF detection [45]. Nevertheless, detection of rhEPO by the on-line CE-ESI-MS technology is still subject to various difficulties, including the concentration of CE buffer, the type, composition and flow-rate of sheath liquid, and the temperature and flow rate of drying gas.…”
Section: Proteinsmentioning
confidence: 99%