Simultaneous and sensitive detection of dopamine and uric acid based on cobalt oxide-decorated graphene oxide composite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 54 publications
0
4
0
Order By: Relevance
“…To solve this problem, different modified electrodes based on the carbon nanomaterials, metal nanoparticles, composites, polymers, and metal oxides have been provided to determine the dopamine [18][19][20]. Recently some nanocomposites containing metal oxides such as CuTRZMoO 4 @PPyÀ n [21], Co 3 O 4 /GO [22], AuÀ ZnO NCAs [23] and TiO 2 À WO 3 [24] have been used for electrochemical determination of DA . In addition, binary transition-metal oxides (BTMOs) due to their superior properties such as better resistance to deactivation, high catalytic activity, and good selectivity have been used in modification of electrodes [25].…”
Section: Introductionmentioning
confidence: 99%
“…To solve this problem, different modified electrodes based on the carbon nanomaterials, metal nanoparticles, composites, polymers, and metal oxides have been provided to determine the dopamine [18][19][20]. Recently some nanocomposites containing metal oxides such as CuTRZMoO 4 @PPyÀ n [21], Co 3 O 4 /GO [22], AuÀ ZnO NCAs [23] and TiO 2 À WO 3 [24] have been used for electrochemical determination of DA . In addition, binary transition-metal oxides (BTMOs) due to their superior properties such as better resistance to deactivation, high catalytic activity, and good selectivity have been used in modification of electrodes [25].…”
Section: Introductionmentioning
confidence: 99%
“…That is, when researchers design electrode materials, EIS is used at each step of the electrode construction process to conrm successful immobilisation of electrode modications. Literature reports that use EIS only in this way have been discounted from this section (there are several examples of this that were ltered from this review from 2021 and 2020 7,[9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] ). Instead, this section seeks to present literature reports of EIS when used as the technique of choice for generating a quantitative analytical signal.…”
Section: Applied Electrochemical Impedance Spectroscopymentioning
confidence: 99%
“…Non-expensive and robust non-enzymatic sensors perform direct oxidation of UA on the surface of the electrode material [ 29 , 30 ]. Various materials, such as covalent organic and metal incorporated conductive polymers [ 13 , 16 , 19 , 23 ], metal oxides [ 30 , 31 , 32 ], carbon-based materials, and their composites [ 11 , 12 , 33 ], have been tested for UA detection [ 5 , 26 ]. These nanomaterials have been recognized as promising materials for the development of analytical methods for the detection not only of UA but also of numerous other biologically active compounds [ 34 , 35 , 36 , 37 ].…”
Section: Introductionmentioning