Simultaneous analysis of cerebrospinal fluid biomarkers using microsphere-based xMAP multiplex technology for early detection of Alzheimer’s disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
58
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 81 publications
(59 citation statements)
references
References 69 publications
1
58
0
Order By: Relevance
“…Tau over-expression is also reported many years following traumatic contusions of the brain [22]. Phosphorylated tau can now even be demonstrated and measured in cerebrospinal fluid of adults with normal pressure hydrocephalus and in dementia tauopathies as a clinical marker of prognosis for dementia and gait impairment [23,37]. m mT TO OR R Hyperactivated mTOR has been identified in HME previously [1,9,10,20] and follows the pattern of tau expression with numerous dysmorphic cells exhibiting phospho-4E-BP1 and phospho-ribosomal S6 protein expression, whereas the contralateral hemisphere does not exhibit these mTOR biomarkers.…”
Section: Discussionmentioning
confidence: 97%
“…Tau over-expression is also reported many years following traumatic contusions of the brain [22]. Phosphorylated tau can now even be demonstrated and measured in cerebrospinal fluid of adults with normal pressure hydrocephalus and in dementia tauopathies as a clinical marker of prognosis for dementia and gait impairment [23,37]. m mT TO OR R Hyperactivated mTOR has been identified in HME previously [1,9,10,20] and follows the pattern of tau expression with numerous dysmorphic cells exhibiting phospho-4E-BP1 and phospho-ribosomal S6 protein expression, whereas the contralateral hemisphere does not exhibit these mTOR biomarkers.…”
Section: Discussionmentioning
confidence: 97%
“…Luminex platforms have the advantages of simultaneous analyses of several biomarkers in one run, reduction of human error, potential of reduced reagent costs, and a modest reduction of sample volume when compared to classical ELISA [31]. The authors found that the BAN50 antibody based assay detected A␤ oligomers, but demonstrated also sA␤PP␣ fragment sensitivity, probably due to the N-terminal epitope of BAN50.…”
Section: Methods For Detection Of A␤ Oligomers In Csf: Elisamentioning
confidence: 99%
“…At the current stage of development, no multiplex immunoassaybased approaches that target 410 analytes have proved sufficiently sensitive to detect beta-amyloid and tau in CSF at the level achieved when optimizing conditions to simultaneously measure these analytes (Kang et al, 2012). Mass spectrometric-based assays offer an unbiased discovery approach (Craft et al, 2013); studies are underway with the same CSF ADNI samples allowing for a unique contrast to the multiplex immunoassay approach.…”
Section: Proteomic Biomarkers For Brain Disorders: Technical Considermentioning