2012
DOI: 10.1021/ac3022086
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Absolute Determination of Particle Size and Effective Density of Submicron Colloids by Disc Centrifuge Photosedimentometry

Abstract: Disc centrifuge photosedimentometry (DCP) with fluids of different densities is used to simultaneously determine the particle size and effective density of spherical silica particles. Incorporation of a calibrated infrared pyrometer into a DCP instrument is shown to enhance the measurement capability of the DCP technique by correcting for the temperature dependence of the spin fluid's density and viscosity. Advantages of absolute DCP determinations for size and density analysis relative to standardized DCP mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 23 publications
0
26
0
Order By: Relevance
“…The corresponding particle size is obtained from the sedimentation time taking density and viscosity profiles into account. 24 Colloidal gold particles with a nominal diameter of 60 nm were used to quantify the density gradient. The disc rotation speed was set to either 10000 or 15000 rpm depending on the particle size.…”
Section: Methodsmentioning
confidence: 99%
“…The corresponding particle size is obtained from the sedimentation time taking density and viscosity profiles into account. 24 Colloidal gold particles with a nominal diameter of 60 nm were used to quantify the density gradient. The disc rotation speed was set to either 10000 or 15000 rpm depending on the particle size.…”
Section: Methodsmentioning
confidence: 99%
“…39 The corrected particle density (ρ ps ) can be estimated by means of two CLS measurements in two media of different density. For estimation of ρ ps of the SAS studied here, the so called 'zero velocity approach' was used.…”
Section: Scanning Electron Microscopy In High Vacuum and Liquid Setupmentioning
confidence: 99%
“…Perhaps more importantly, the lack of radial scans monitoring the entire solution column prohibits diagnostics of systematic errors in the model or experimental problems, including significant contributions to particle migration from diffusion, convection, systematic noise contributions, and/or signal offsets from sedimenting small co-solute molecules. Fixed-radius detection has been applied recently in conjunction with a multiwavelength detector design for AUC 55 , and is used in disc centrifuges 5658 . However, in the latter approach, similar to band centrifugation configurations in AUC, samples are injected causing sedimenting lamella that will exhibit reduced, but more complex simultaneous detection and radial dilution effects.…”
Section: Resultsmentioning
confidence: 99%