2013
DOI: 10.7763/ijmlc.2013.v3.351
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of Human Eye Optical System Properties and Depth of Field Variation

Abstract: Abstract-Human eyes are not perfect optical systems, most of them have refractive errors, the simulation of which is a plus to the realistic vision rendering. This paper presents the simulation of the properties of human eye optical system with an abstracted human eye optical model, including myopia, hyperopia and astigmatism. A novel and effective ray-tracing-based method is brought out in this paper, which calculates the direction of rays refracted by the eye without modeling the surface of the crystalline l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…The intersection tests were very costly, the input was limited to 2D images, and chromatic aberration was ignored Wu et al [11] The authors used aspherical refractive eye elements to improve the peripheral simulation accuracy and bidirectional path tracing with 3D scenes to guarantee that no rays are blocked by the pupil Chromatic aberration was ignored and the flat retina shape caused incorrect peripheral blurring Wang and Xiao [12] This algorithm utilized spectacle lens prescriptions for a fast simulation of myopia, hyperopia, and astigmatism, and a novel simplified geometrical formulation for a stripped-down eye model to efficiently calculate the refracted ray directions…”
Section: Reference Methods Used and Main Innovation Main Limitationmentioning
confidence: 99%
See 2 more Smart Citations
“…The intersection tests were very costly, the input was limited to 2D images, and chromatic aberration was ignored Wu et al [11] The authors used aspherical refractive eye elements to improve the peripheral simulation accuracy and bidirectional path tracing with 3D scenes to guarantee that no rays are blocked by the pupil Chromatic aberration was ignored and the flat retina shape caused incorrect peripheral blurring Wang and Xiao [12] This algorithm utilized spectacle lens prescriptions for a fast simulation of myopia, hyperopia, and astigmatism, and a novel simplified geometrical formulation for a stripped-down eye model to efficiently calculate the refracted ray directions…”
Section: Reference Methods Used and Main Innovation Main Limitationmentioning
confidence: 99%
“…To overcome these issues, Wang and Xiao [12] used a simple eye model comprising a convex lens, pupil, and flat retina. This stripped-down model allows for the derivation of simple geometrical formulas for eyes with myopia, hyperopia, and astigmatism.…”
Section: Reducing Trace Complexitymentioning
confidence: 99%
See 1 more Smart Citation