2002
DOI: 10.1109/20.996295
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of forces and 3-D field arising during power autotransformer fault due to electric arc in HV winding

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…AST construction is based on the well-known structures of the three-phase transformers with magnetically symmetrical cores given by Doliwo-Dobrowolski (Zakrzewski et al, 2002). He developed and patented such construction towards the end of the nineteenth century in the USA ( Jabłoński, 2002).…”
Section: Description Of the Objects And Calculation Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…AST construction is based on the well-known structures of the three-phase transformers with magnetically symmetrical cores given by Doliwo-Dobrowolski (Zakrzewski et al, 2002). He developed and patented such construction towards the end of the nineteenth century in the USA ( Jabłoński, 2002).…”
Section: Description Of the Objects And Calculation Modelsmentioning
confidence: 99%
“…As AST has symmetrical structure, the region to be analyzed has been halved along the XZ-plane (Figure 1) (Zakrzewski et al, 2002). Assuming one moment in the three-phase current waveforms, only a part of the AST can be taken into consideration.…”
Section: Amorphous Modular Transformersmentioning
confidence: 99%
“…1 are presented the loss values in silicon steel sheets and in amorphous ribbons versus the magnetic flux density values. In the amorphous alloy, the core losses are several times lower than in grain-oriented silicon steel [4,8,10]. Thus, the amorphous core is more efficient for electromagnetic energyconversion devices than the traditional one.…”
Section: Introductionmentioning
confidence: 96%
“…This leads to the reduction of total losses of the power system. For the mode of load and noload operations, the main parameters of transformers must be concerned such as efficiency, loss, temperature rise, and core weight [5][6][7][8]. As a sudden short-circuit in the low-voltage winding of the transformer or a short-circuit between connected turns occurs, the magnetic flux distribution in the magnetic circuit is small, but the leakage/fringing flux in the air gap is very large.…”
Section: Introductionmentioning
confidence: 99%